EUVIMEDEUVIMED entdecken
KohortenstudieOpen Access · CC BY 4.0

Ultrasound predictors of peripheral nerve block failure after blast injury: a prospective cohort study

Dmytro Dmytriiev

Frontiers in Medicine · 06.07.2026 · 13

DOI: 10.3389/fmed.2026.1826698 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Frontiers in Medicine, online erschienen am 06.07.2026. Verfasst von Dmytro Dmytriiev. Beteiligte Einrichtung: Superhumans War Trauma Center, Lviv, Ukraine. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

High-energy blast injuries produce severe anatomical distortion that may compromise ultrasound-guided peripheral nerve blocks (PNBs). However, large-scale data identifying predictors of block failure in this population remain limited.

Objective

To determine the incidence and independent predictors of PNB failure in patients with blast-related limb trauma.

Methods

Prospective observational cohort study conducted between March 2023 and February 2026 at a tertiary war trauma center. Adult patients undergoing ultrasound-guided PNB for blast-related limb injuries were included. Primary block failure was defined as failure to achieve ≥50% reduction in Numeric Rating Scale (NRS) pain score within 30 min together with incomplete sensory blockade in the expected dermatomal distribution. Rescue opioid requirement within 6 h was analyzed separately as a secondary indicator of analgesic burden. Anatomical distortion variables and injury severity were analyzed. Multivariable logistic regression identified independent predictors of failure.

Results

A total of 774 patients were analyzed. Overall block failure rate was 27.8%. Anatomical distortion was present in 64% of cases. Independent predictors of failure included vascular reconstruction (aOR 2.43, 95% CI 1.65–3.58), large hematoma (aOR 1.91, 95% CI 1.43–2.55), scar tissue/adhesions (aOR 1.74, 95% CI 1.29–2.33), fracture displacement (aOR 1.68, 95% CI 1.25–2.24), and Injury Severity Score > 25 (aOR 1.56, 95% CI 1.14–2.13).

Conclusion

Anatomical distortion following blast injury significantly increases the risk of PNB failure. Recognition of trauma-specific anatomical predictors is essential for optimizing regional anesthesia strategies in high-energy injury populations.

Schlagwörter

Stichwörter der Autor:innen

anatomical distortionblast injuryblock failurehematomaperipheral nerve blockregional anesthesiatrauma anesthesiaultrasound-guided nerve block

Autor:innen und Institutionen

  • Superhumans War Trauma Center, Lviv, Ukraine.
  • Department of Anesthesiology and Intensive Care, National Pirogov Memorial Medical University, Vinnytsia, Ukraine.

Zitieren

APA

Dmytriiev, D. (2026). Ultrasound predictors of peripheral nerve block failure after blast injury: a prospective cohort study. Frontiers in Medicine, 13. https://doi.org/10.3389/fmed.2026.1826698

Vancouver

Dmytriiev D. Ultrasound predictors of peripheral nerve block failure after blast injury: a prospective cohort study. Frontiers in Medicine. 2026;13. doi:10.3389/fmed.2026.1826698

BibTeX
@article{Dmytriiev2026,
  author = {Dmytriiev, Dmytro},
  title = {Ultrasound predictors of peripheral nerve block failure after blast injury: a prospective cohort study},
  journal = {Frontiers in Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fmed.2026.1826698}
}
Kostenlos starten →