EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Direct, minimally intrusive quantification of rebreathing in the circle breathing system during spontaneous breathing: a proof-of-concept feasibility study

Jie Cui, Yanling Tan, Pan Li

Frontiers in Medicine · 08.07.2026 · 13

DOI: 10.3389/fmed.2026.1780197 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Medicine, online erschienen am 08.07.2026. Verfasst von Jie Cui und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Children's Hospital of Chongqing Medical University, National Clinical Research Center for Children and Adolescents' He…. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

During spontaneous breathing in the circle breathing system, hypercapnia can occur partly due to the rebreathing in the breathing tubing; however, there is currently no explicit method to quantify this specific portion of rebreathing.

Methods

We derived formulas from the ideal gas law to calculate the rebreathing. To conduct an initial proof-of-concept feasibility assessment, we applied these formulas to data from only one pediatric patient—a 5-year-old child under general anesthesia. Spontaneous breathing was maintained with fresh gas flow of 2, 4, and 6 L/min, with real-time monitoring of gas states within the breathing tubing.

Results

The total maximum rebreathing volumes originating from the breathing tubing were 0.54 ± 0.05 mL, 0.47 ± 0.03 mL, and 0.43 ± 0.03 mL, respectively, showing a decreasing trend with increasing fresh gas flow.

Conclusion

Spontaneous breathing via the circle breathing system leads to rebreathing from the breathing tubing, and the specific value of the rebreathing resulting from the breathing tubing can be calculated using the formulas obtained from the ideal gas law.

Schlagwörter

Stichwörter der Autor:innen

breathing tubingcircle breathing systemideal gasrebreathingspontaneous breathing

Autor:innen und Institutionen

  • Department of Anesthesiology, Children's Hospital of Chongqing Medical University, National Clinical Research Center for Children and Adolescents' Health and Diseases, Ministry of Education Key Laboratory of Child Devel…

Zitieren

APA

Cui, J., Tan, Y., & Li, P. (2026). Direct, minimally intrusive quantification of rebreathing in the circle breathing system during spontaneous breathing: a proof-of-concept feasibility study. Frontiers in Medicine, 13. https://doi.org/10.3389/fmed.2026.1780197

Vancouver

Cui J, Tan Y, Li P. Direct, minimally intrusive quantification of rebreathing in the circle breathing system during spontaneous breathing: a proof-of-concept feasibility study. Frontiers in Medicine. 2026;13. doi:10.3389/fmed.2026.1780197

BibTeX
@article{Cui2026,
  author = {Cui, Jie and Tan, Yanling and Li, Pan},
  title = {Direct, minimally intrusive quantification of rebreathing in the circle breathing system during spontaneous breathing: a proof-of-concept feasibility study},
  journal = {Frontiers in Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fmed.2026.1780197}
}
Kostenlos starten →