Diagnostic accuracy and safety of Diaskintest® compared with the tuberculin skin test for detecting tuberculosis infection in BCG-vaccinated Brazilian adults
Frontiers in Medicine · 27.01.2026 · 13
DOI: 10.3389/fmed.2026.1736211 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Medicine, online erschienen am 27.01.2026. Verfasst von Afrânio Kritski und 14 weiteren Autor:innen. Beteiligte Einrichtung: Hospital Universitário Clementino Fraga Filho/Instituto de Doenças do Tórax, Escola de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janei…. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Evidence on the accuracy and safety of the ESAT-6/CFP-10–based Diaskintest ® in BCG-vaccinated populations outside Eastern Europe remains limited. In Brazil, recurrent shortages of purified protein derivative (PPD) have challenged the implementation of tuberculin skin testing, underscoring the need to evaluate alternative tools for tuberculosis infection (TBI) screening. This trial compared the diagnostic performance and safety of Diaskintest ® with the tuberculin skin test (TST) using PPD Rt-23 in Brazilian adults, a predominantly BCG-vaccinated population.
Method
A double-blind randomized clinical trial was conducted at eight centers in Brazil between July 2023 and September 2024. Participants were allocated to the TB group (microbiologically confirmed pulmonary TB), in whom sensitivity was estimated, and the control group (healthy, unexposed adults), in whom specificity was estimated using the QuantiFERON-TB Plus ® (QFT-Plus) as the reference standard. All participants first underwent QFT-Plus testing, followed by intradermal application of Diaskintest ® and TST in opposite arms, with randomized right–left allocation. Induration was measured at 48–96 h using a prespecified 5 mm cutoff. Secondary outcomes included safety, assessed through active monitoring of adverse events (AEs), included injection site reactions.
Results
A total of 337 controls and 136 TB participants were enrolled. TST showed higher sensitivity than both Diaskintest and QFT-plus (0.84 [95% CI 0.76–0.90] vs. 0.68 [95% CI 0.59–0.76], and 0.63 [95% CI 0.54–0.72], respectively). Diaskintest ® demonstrated higher specificity than TST (0.93 [95% CI 0.90–0.96] vs. 0.75 [95% CI 0.70–0.80]). Injection-site reactions occurred less frequently with Diaskintest ® than with TST (1.7% vs. 4.9%. RR = 0.35 [0.15–0.79]). The most common reactions were phlyctenular reactions and itching. No serious AEs were observed.
Conclusion
TST had greater sensitivity than Diaskintest ® , whereas Diaskintest ® demonstrated higher specificity and fewer local adverse reactions. In this study, specificity was estimated using QFT-Plus as a surrogate reference standard, acknowledging the absence of a true gold standard for tuberculosis infection. These complementary performance profiles highlight a trade-off between false-positive reduction and case detection, suggesting that the choice of test should consider programmatic priorities and local epidemiological context. Clinical trial registration https://ensaiosclinicos.gov.br/ , identifier RBR-7tn2ysw.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hospital Universitário Clementino Fraga Filho/Instituto de Doenças do Tórax, Escola de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil.
- Laboratório de Micobacteriologia Molecular, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil.
- Fundação de Medicina Tropical Dr. Heitor Vieira Dourado, Manaus, Brazil.
- School of Medicine, Universidade do Estado do Amazonas, Manaus, Brazil.
- School of Medicine, Universidade Nilton Lins, Manaus, Brazil.
- Centro Municipal de Saúde de Duque de Caxias, Municipal Health Secretariat, Duque de Caxias, Brazil.
Zitieren
APA
Kritski, A., Conceição, C., Oliveira, M., Dalvi, A. P. R., Cordeiro-Santos, M., Moreira, A. R., Lopes, A., Ruffino, R., Rodrigues, L., Mesquita, E., Cardozo, S. V., Pereira, M. J. F., Sakabe, S., Trajman, A., & Bhering, M. (2026). Diagnostic accuracy and safety of Diaskintest® compared with the tuberculin skin test for detecting tuberculosis infection in BCG-vaccinated Brazilian adults. Frontiers in Medicine, 13. https://doi.org/10.3389/fmed.2026.1736211
Vancouver
Kritski A, Conceição C, Oliveira M, Dalvi APR, Cordeiro-Santos M, Moreira AR, et al. Diagnostic accuracy and safety of Diaskintest® compared with the tuberculin skin test for detecting tuberculosis infection in BCG-vaccinated Brazilian adults. Frontiers in Medicine. 2026;13. doi:10.3389/fmed.2026.1736211
BibTeX
@article{Kritski2026,
author = {Kritski, Afrânio and Conceição, Carla and Oliveira, Martha and Dalvi, Ana Paula Razal and Cordeiro-Santos, Marcelo and Moreira, Adriana Rezende and Lopes, Aline and Ruffino, Rogerio and Rodrigues, Luciana and Mesquita, Eliene and Cardozo, Sergian Vianna and Pereira, Maria Jose Fernandes and Sakabe, Sumire and Trajman, Anete and Bhering, Marcela},
title = {Diagnostic accuracy and safety of Diaskintest® compared with the tuberculin skin test for detecting tuberculosis infection in BCG-vaccinated Brazilian adults},
journal = {Frontiers in Medicine},
year = {2026},
volume = {13},
doi = {10.3389/fmed.2026.1736211}
}
EUVIMED