Visual outcomes with a non-diffractive enhanced depth-of-focus IOL in patients with age-related macular degeneration
Frontiers in Medicine · 13.06.2025 · 12
DOI: 10.3389/fmed.2025.1505401 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Medicine, online erschienen am 13.06.2025. Verfasst von Juan Carlos Elvira und 5 weiteren Autor:innen. Beteiligte Einrichtung: Oftalvist, Alicante, Spain. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To evaluate visual function in eyes with age-related macular degeneration (AMD) implanted with a non-diffractive enhanced depth-of-focus (EDOF) intraocular lens (IOL) after cataract surgery.
Design
Prospective, observational, non-randomized clinical study.
Methods
Twenty-two eyes from 22 patients diagnosed with AMD and cataracts were submitted to standard cataract surgery with a non-diffractive EDOF IOL implantation (AcrySof IQ Vivity). We measured monocular uncorrected and best-corrected-distance visual acuity (UDVA and CDVA), uncorrected- and distance-corrected-intermediate visual acuity (UIVA and DCIVA), uncorrected- and distance-corrected-near visual acuity (UNVA and DCNVA), manifest refractive spherical equivalent (MRSE) and cylinder, monocular defocus curve and patient-reported outcome questionnaires (Catquest-9SF and NEI VFQ-25). Follow-up visits were carried out at 1, 3 and 6 months post-surgery.
Results
At 6 months post-surgery all eyes were within ± 0.50 D with a mean MRSE of −0.19 ± 0.20 D, 95.45% had a refractive cylinder of ≤ 0.50 D with a mean cylinder of −0.24 ± 0.27 D. The mean values of postoperative monocular CDVA, DCIVA, and DCNVA were 0.02 ± 0.08, 0.16 ± 0.11, and 0.26 ± 0.15 logMAR, respectively. The defocus curve showed good visual acuity at distance and intermediate with a depth-of-focus of about 1.60 D. A total of 81.82% of patients did not report any difficulty with their vision in their everyday-life and 86.36% reported being quite satisfied to very satisfied with their current vision. The NEI VFQ-25 showed that all values improved significantly ( p < 0.05) after the surgery in the different parameters analyzed except for ocular pain ( p = 0.390) and color vision ( p = 0.333).
Conclusion
The use of a non-diffractive EDOF IOL in AMD eyes with cataracts is a safe and effective surgical approach for visually correcting aphakia, providing good visual acuity at far and intermediate distances. Our outcomes support the use of non-diffractive EDOF IOLs in patients with AMD diagnosed with cataracts aiming to obtain spectacle-independence at far and intermediate distances.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Oftalvist, Alicante, Spain.
Zitieren
APA
Elvira, J. C., Devesa, P., Elvira-Giner, B., Tañá-Sanz, P., Orts-Vila, P., & Tañá-Rivero, P. (2025). Visual outcomes with a non-diffractive enhanced depth-of-focus IOL in patients with age-related macular degeneration. Frontiers in Medicine, 12. https://doi.org/10.3389/fmed.2025.1505401
Vancouver
Elvira JC, Devesa P, Elvira-Giner B, Tañá-Sanz P, Orts-Vila P, Tañá-Rivero P. Visual outcomes with a non-diffractive enhanced depth-of-focus IOL in patients with age-related macular degeneration. Frontiers in Medicine. 2025;12. doi:10.3389/fmed.2025.1505401
BibTeX
@article{Elvira2025,
author = {Elvira, Juan Carlos and Devesa, Patricia and Elvira-Giner, Belén and Tañá-Sanz, Pedro and Orts-Vila, Paz and Tañá-Rivero, Pedro},
title = {Visual outcomes with a non-diffractive enhanced depth-of-focus IOL in patients with age-related macular degeneration},
journal = {Frontiers in Medicine},
year = {2025},
volume = {12},
doi = {10.3389/fmed.2025.1505401}
}
EUVIMED