Fachartikel in der Zeitschrift Frontiers in Medicine, online erschienen am 14.02.2023. Verfasst von Cheng Wan und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Electronic Information Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Tear meniscus height (TMH) is an important reference parameter in the diagnosis of dry eye disease. However, most traditional methods of measuring TMH are manual or semi-automatic, which causes the measurement of TMH to be prone to the influence of subjective factors, time consuming, and laborious. To solve these problems, a segmentation algorithm based on deep learning and image processing was proposed to realize the automatic measurement of TMH. To accurately segment the tear meniscus region, the segmentation algorithm designed in this study is based on the DeepLabv3 architecture and combines the partial structure of the ResNet50, GoogleNet, and FCN networks for further improvements. A total of 305 ocular surface images were used in this study, which were divided into training and testing sets. The training set was used to train the network model, and the testing set was used to evaluate the model performance. In the experiment, for tear meniscus segmentation, the average intersection over union was 0.896, the dice coefficient was 0.884, and the sensitivity was 0.877. For the central ring of corneal projection ring segmentation, the average intersection over union was 0.932, the dice coefficient was 0.926, and the sensitivity was 0.947. According to the evaluation index comparison, the segmentation model used in this study was superior to the existing model. Finally, the measurement outcome of TMH of the testing set using the proposed method was compared with manual measurement results. All measurement results were directly compared via linear regression; the regression line was y0.98x−0.02, and the overall correlation coefficient was r 2 0.94. Thus, the proposed method for measuring TMH in this paper is highly consistent with manual measurement and can realize the automatic measurement of TMH and assist clinicians in the diagnosis of dry eye disease.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Electronic Information Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China.
- Shenzhen Eye Hospital, Jinan University, Shenzhen, China.
- Shenzhen Eye Institute, Shenzhen, China.
Zitieren
APA
Wan, C., Hua, R., Guo, P., Lin, P., Wang, J., Yang, W., & Hong, X. (2023). Measurement method of tear meniscus height based on deep learning. Frontiers in Medicine, 10. https://doi.org/10.3389/fmed.2023.1126754
Vancouver
Wan C, Hua R, Guo P, Lin P, Wang J, Yang W, et al. Measurement method of tear meniscus height based on deep learning. Frontiers in Medicine. 2023;10. doi:10.3389/fmed.2023.1126754
BibTeX
@article{Wan2023,
author = {Wan, Cheng and Hua, Rongrong and Guo, Ping and Lin, Peijie and Wang, Jiantao and Yang, Weihua and Hong, Xiangqian},
title = {Measurement method of tear meniscus height based on deep learning},
journal = {Frontiers in Medicine},
year = {2023},
volume = {10},
doi = {10.3389/fmed.2023.1126754}
}
EUVIMED