Building seismic optimization using tuned viscous mass dampers

Yongbin Jia

Frontiers in Mechanical Engineering · 03.06.2026 · 12

DOI: 10.3389/fmech.2026.1826322 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Mechanical Engineering, online erschienen am 03.06.2026. Verfasst von Yongbin Jia. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Building seismic optimization plays a key role in ensuring structural safety and functionality. Existing technologies show limited multi-objective coordination and face difficulties in parameter adjustment when dealing with complex structures and extreme seismic conditions.

Methods

This study proposes a comprehensive seismic optimization technique that combines Particle Swarm Optimization (PSO) with Tuned Viscous Mass Dampers (TVMD), and integrates Wavelet Transform Support Vector Machine (WT-SVM) and Deep Belief NetworkAdaptive Weighting Mechanism (DBN-AWM), ultimately constructing the DBNAWM-WPPT (DAWPT) seismic optimization technique for buildings. This technique first uses WT to decompose seismic ground motions at multiple scales and extract dominant frequency band features. Then, SVM is used to establish a predictive surrogate model for damping performance under nonlinear conditions. DBN-AWM deeply integrates high-dimensional seismic features from multi-dimensional monitoring data and dynamically adjusts the fitness weights of multiple objectives. Based on this, PSO uses the control parameters of TVMD as decision variables to perform collaborative iterative optimization under simulated seismic conditions, ultimately outputting a parameter configuration scheme that balances seismic activity suppression, economic cost, and structural stability.

Results

Experimental results show that the DAWPT technique achieves an optimization convergence efficiency of 97.23%, a response spectrum matching degree of 97.23% within the 0.one to two Hz seismic wave input frequency band, and a multimodal vibration control synchronization rate of 95.45% in actual high-rise office building tests, all significantly better than the comparative methods.

Discussion

This technology effectively improves the multi-objective optimization efficiency and seismic adaptability of complex buildings under extreme conditions, providing efficient and reliable technical support for seismic design.

Zitieren

APA

Jia, Y. (2026). Building seismic optimization using tuned viscous mass dampers. Frontiers in Mechanical Engineering, 12. https://doi.org/10.3389/fmech.2026.1826322

Vancouver

Jia Y. Building seismic optimization using tuned viscous mass dampers. Frontiers in Mechanical Engineering. 2026;12. doi:10.3389/fmech.2026.1826322

BibTeX
@article{Jia2026,
  author = {Jia, Yongbin},
  title = {Building seismic optimization using tuned viscous mass dampers},
  journal = {Frontiers in Mechanical Engineering},
  year = {2026},
  volume = {12},
  doi = {10.3389/fmech.2026.1826322}
}
Kostenlos starten →