EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Performance evaluation of a moving bed biofilm reactor for hospital wastewater treatment: removal efficiency, seasonal variability, and risk assessment

Shiyu Guo, Lianchuan Xiao, Chunming Tao

Frontiers in Environmental Science · 02.04.2026 · 14

DOI: 10.3389/fenvs.2026.1813954 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Environmental Science, online erschienen am 02.04.2026. Verfasst von Shiyu Guo und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hospital wastewater poses significant environmental and public health risks due to pathogenic microorganisms, pharmaceutical residues, and heavy metals. A 1-year temporal analysis of the hospital wastewater treatment system was conducted, involving a systematic evaluation of seasonal and monthly variations of above pollutants. The chemical oxygen demand (COD) concentration at the hospital wastewater treatment plant (HWTP) outlet peaked at 85 mg/L in summer. The suspended solids (SS) concentration exhibited an increasing trend over time, reaching a maximum of 38.3 mg/L at the end of the year. The highest concentration of fecal coliforms (FCs) (3.2 × 10 3 MPN/L) appeared in May 2024. The moving bed biofilm reactor (MBBR) process demonstrates good performance in removing pollutants, such as ammonia nitrogen (NH 3 -N), COD, SS, FCs for hospital wastewater. The average removal rates of above pollutants reached 99.9%, 79.0%, 82.6%, and 71.5% respectively. Moreover, this study further investigates the emission patterns of fugitive gases (H 2 S, NH 3 , Cl 2 ) from different azimuths around the HWTP. The concentrations of the six heavy metals in the effluent of the HWTP were all lower than the discharge standards. Both the single-factor pollution index (P i ) and the Nemerow pollution index (P N ) were less than 0.1, indicating a low risk of heavy metal pollution. It provides a theoretical basis and practical guidance for the regulation of hospital wastewater and the optimization of operational parameters for treatment processes.

Zitieren

APA

Guo, S., Xiao, L., & Tao, C. (2026). Performance evaluation of a moving bed biofilm reactor for hospital wastewater treatment: removal efficiency, seasonal variability, and risk assessment. Frontiers in Environmental Science, 14. https://doi.org/10.3389/fenvs.2026.1813954

Vancouver

Guo S, Xiao L, Tao C. Performance evaluation of a moving bed biofilm reactor for hospital wastewater treatment: removal efficiency, seasonal variability, and risk assessment. Frontiers in Environmental Science. 2026;14. doi:10.3389/fenvs.2026.1813954

BibTeX
@article{Guo2026,
  author = {Guo, Shiyu and Xiao, Lianchuan and Tao, Chunming},
  title = {Performance evaluation of a moving bed biofilm reactor for hospital wastewater treatment: removal efficiency, seasonal variability, and risk assessment},
  journal = {Frontiers in Environmental Science},
  year = {2026},
  volume = {14},
  doi = {10.3389/fenvs.2026.1813954}
}
Kostenlos starten →