EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation and improvement of power quality of distribution network: a case study of Covenant University, Ota

Isaac A. Samuel, Daudu Afah Toyin, Tobiloba E. Somefun, Ayokunle A. Awelewa, Shehu Abba-Aliyu

Frontiers in Energy Efficiency · 2025

DOI: 10.3389/fenef.2024.1389622 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Energy Efficiency, 2025. Verfasst von Isaac A. Samuel und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Power quality is a global concern, particularly as electronic devices are increasingly supporting modern economies. This research evaluates and proposes improvements for power quality of the distribution network at Covenant University, Ota, Nigeria, where electrical equipment usage contributes to power quality challenges. Measurements and evaluations were carried out in three stages: first, measuring power quality at five campus powerhouses using a Circutor aR6 power analyzer; second, assessing these measurements with Power Vision software; third, simulating the evaluated network with NEPLAN software. The study was conducted during an active school session, with measurements taken at 500 kVA, 11 kV/415 V/230 V on the outgoing circuits for each transformer. The results were benchmarked against IEEE power quality standards and identified issues such as harmonics, total harmonic distortion (THD), overload, and a lagging power factor. The proposed improvements, derived from NEPLAN simulation, included active harmonic filters to reduce harmonics, a shunt capacitor for power factor correction, and load sharing for managing transformer overloads. Simulation results demonstrated that THD was significantly reduced across all powerhouses: CDS from 7.28% to 0.91%, EIE from 10.52% to 3.54%, CST from 16.03% to 0.58%, the Library from 11.92% to 0.12%, and the Male Hostel from 16.71% to 0.24%. These adjustments enhanced THD within specified limits. Additionally, the shunt capacitor increased the power factor to 0.96 from −0.96. These enhancements are expected to extend equipment life, reduce heat loss, and lower utility costs.

Zitieren

APA

Samuel, I. A., Toyin, D. A., Somefun, T. E., Awelewa, A. A., & Abba-Aliyu, S. (2025). Evaluation and improvement of power quality of distribution network: a case study of Covenant University, Ota. Frontiers in Energy Efficiency. https://doi.org/10.3389/fenef.2024.1389622

Vancouver

Samuel IA, Toyin DA, Somefun TE, Awelewa AA, Abba-Aliyu S. Evaluation and improvement of power quality of distribution network: a case study of Covenant University, Ota. Frontiers in Energy Efficiency. 2025. doi:10.3389/fenef.2024.1389622

BibTeX
@article{Samuel2025,
  author = {Samuel, Isaac A. and Toyin, Daudu Afah and Somefun, Tobiloba E. and Awelewa, Ayokunle A. and Abba-Aliyu, Shehu},
  title = {Evaluation and improvement of power quality of distribution network: a case study of Covenant University, Ota},
  journal = {Frontiers in Energy Efficiency},
  year = {2025},
  doi = {10.3389/fenef.2024.1389622}
}
Kostenlos starten →