EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of mold materials and their hydration on the setting time of hydraulic root canal sealers: a laboratory study

Vasileios Kapralos, Racheal Bartling, Andrea Gubler, Matthias Zehnder

Frontiers in Dental Medicine · 18.11.2026 · 7

DOI: 10.3389/fdmed.2026.2013551 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Dental Medicine, online erschienen am 18.11.2026. Verfasst von Vasileios Kapralos und 3 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The International Organization for Standardization (ISO) norm 6876 on root canal sealing materials has been amended three times. There have been inconsistencies in the different versions regarding the molds to be used when testing the setting time of hydraulic sealers. Materials and methods Molds of a geometric design according to ISO 6876 were prepared from bovine dentin, polyethylene terephthalate (PET), and gypsum. They were kept hydrated or were dehydrated prior to application of the sealers. Setting time was then tested in 100% humidity at 37 °C using a Gillmore apparatus. Further experiments were performed to explain the results observed with the gypsum molds. Two-way ANOVA was applied to analyze the influence of mold material and its hydration status on setting time for each sealer separately ( n = 7).

Results

The mold material had a strong influence ( P < 0.001) on the setting time of BioRoot RCS, and a weaker, though statistically significant, effect on the setting time of BioRoot Flow. Mold hydration prior to testing had no impact at all. With BioRoot RCS, the gypsum molds caused a 3-fold longer setting time compared to the dentin and the PET counterparts. This was explained by capillary-driven transport of the aqueous BioRoot RCS phase through the porous gypsum structure rather than any chemical reactions between sealer and mold.

Conclusion

Mold hydration appears to play no role in ISO 6876 setting time assessment, because the water is absorbed from the humid environment by the hydraulic sealers through their exposed surface. Molds preventing water leakage appear to provide more consistent results than gypsum does.

Zitieren

APA

Kapralos, V., Bartling, R., Gubler, A., & Zehnder, M. (2026). Influence of mold materials and their hydration on the setting time of hydraulic root canal sealers: a laboratory study. Frontiers in Dental Medicine, 7. https://doi.org/10.3389/fdmed.2026.2013551

Vancouver

Kapralos V, Bartling R, Gubler A, Zehnder M. Influence of mold materials and their hydration on the setting time of hydraulic root canal sealers: a laboratory study. Frontiers in Dental Medicine. 2026;7. doi:10.3389/fdmed.2026.2013551

BibTeX
@article{Kapralos2026,
  author = {Kapralos, Vasileios and Bartling, Racheal and Gubler, Andrea and Zehnder, Matthias},
  title = {Influence of mold materials and their hydration on the setting time of hydraulic root canal sealers: a laboratory study},
  journal = {Frontiers in Dental Medicine},
  year = {2026},
  volume = {7},
  doi = {10.3389/fdmed.2026.2013551}
}
Kostenlos starten →