EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A simulation-based optimization framework for calibration of a digital twin in a sleep-disordered breathing unit

Ein simulationsbasiertes Optimierungsrahmenwerk zur Kalibrierung eines digitalen Zwillings in einer Einheit für schlafbezogene Atmungsstörungen

Jaime Álvarez-Vázquez, Manuel Casal-Guisande, José-Benito Bouza-Rodríguez, Mar Mosteiro-Añón, Alberto Fernández-Villar, María Torres-Durán

Frontiers in Digital Health · 09.11.2026 · 8

DOI: 10.3389/fdgth.2026.1900707 ↗

Auf einen Blick

Eine simulationsbasierte Optimierung wurde mit einem DES-Modell zur Kalibrierung eines digitalen Zwillings in einer Einheit für schlafbezogene Atmungsstörungen getestet. Für die mittlere Zahl wartender Patient:innen sank die globale gewichtete RPD von 3,6 % auf 1,11 %.

Fragestellung

Lässt sich die Kalibrierung der Zustandsübergangsmatrix in einem digitalen Zwilling einer Einheit für schlafbezogene Atmungsstörungen mit simulationsbasierter Optimierung automatisieren?

Methode

Diskrete-Ereignis-Simulation mit simulationsbasierter Optimierung in MATLAB © zur automatischen Kalibrierung der Zustandsübergangsmatrix.

Ergebnisse

Im Hauptversuch sank die globale gewichtete RPD für die mittlere Zahl wartender Patient:innen von 3,6 % bei manueller Kalibrierung auf 1,11 %. Weitere Experimente priorisierten klinisch relevante Phasen, teils mit höherem Gesamtfehler.

Einschränkungen

Manuelle Kalibrierung war zeitaufwendig und iterativ; zusätzliche Experimente konnten den Fehler des Queue-Indikators erhöhen.

Schlussfolgerung der Autor:innen

Nach Ansicht der Autor:innen ist dies die erste Anwendung von SBO zur automatisierten Kalibrierung einer Zustandsübergangsmatrix in einem DES-Modell dieser Einheit und eine quantitativ wirksame Alternative zur manuellen Parametrierung.

Kernaussagen

  • RPD für die mittlere Zahl wartender Patient:innen: 3,6 % auf 1,11 %
  • SBO automatisierte die Kalibrierung der Zustandsübergangsmatrix
  • Priorisierung klinisch relevanter Phasen war möglich, teils mit mehr Gesamtfehler

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Digital Health, online erschienen am 09.11.2026. Verfasst von Jaime Álvarez-Vázquez und 5 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sleep-disordered breathing, and obstructive sleep apnea in particular, places sustained demand on specialized units, leading to prolonged waiting lists that in some settings exceed one year for diagnostic tests such as respiratory polygraphy (PLG). In a previous study, a discrete-event simulation (DES) model was developed and validated as a digital twin of the patient flow in the Sleep-Disordered Breathing Unit of the Pulmonology Department at Hospital Álvaro Cunqueiro (Vigo, Spain), yielding a weighted Relative Percent Difference (RPD) of 3.6% for the mean number of patients in queue and 34.6% for the mean waiting time relative to real-world data. However, the transition probabilities governing patient routing across care stages were manually calibrated through a time-consuming, iterative process based on expert judgment, which limits the reproducibility and optimality of the solution. To address this limitation, the present study proposes and evaluates a simulation-based optimization (SBO) framework coupled to the DES model, implemented in MATLAB © , with the goal of automating the calibration of the state-transition matrix. In the main experiment, aimed at calibrating the mean number of patients in queue, the optimal solution reduced the global weighted RPD for this indicator from 3.6% under manual calibration to 1.11%. Complementary experiments that incorporated waiting time into the objective function or redistributed stage weights toward PLG confirmed the ability of the SBO framework to prioritize clinically relevant stages, at the potential cost of increased aggregate error in the queue indicator. To the best of our knowledge, this is the first application of SBO to the automated calibration of a state-transition matrix in a DES model of a sleep-disordered breathing unit, offering a quantitatively effective alternative to manual parameter tuning.

Zitieren

APA

Álvarez-Vázquez, J., Casal-Guisande, M., Bouza-Rodríguez, J., Mosteiro-Añón, M., Fernández-Villar, A., & Torres-Durán, M. (2026). A simulation-based optimization framework for calibration of a digital twin in a sleep-disordered breathing unit. Frontiers in Digital Health, 8. https://doi.org/10.3389/fdgth.2026.1900707

Vancouver

Álvarez-Vázquez J, Casal-Guisande M, Bouza-Rodríguez J, Mosteiro-Añón M, Fernández-Villar A, Torres-Durán M. A simulation-based optimization framework for calibration of a digital twin in a sleep-disordered breathing unit. Frontiers in Digital Health. 2026;8. doi:10.3389/fdgth.2026.1900707

BibTeX
@article{lvarezVzquez2026,
  author = {Álvarez-Vázquez, Jaime and Casal-Guisande, Manuel and Bouza-Rodríguez, José-Benito and Mosteiro-Añón, Mar and Fernández-Villar, Alberto and Torres-Durán, María},
  title = {A simulation-based optimization framework for calibration of a digital twin in a sleep-disordered breathing unit},
  journal = {Frontiers in Digital Health},
  year = {2026},
  volume = {8},
  doi = {10.3389/fdgth.2026.1900707}
}
Kostenlos starten →