EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Diagnostic delays and data integrity risks in medical imaging systems: a qualitative case report using incident classification and risk–control analysis

Bushra Rehan, Abdallah Hassoun, Md Shafiqur Rahman Jabin

Frontiers in Digital Health · 17.11.2026 · 8

DOI: 10.3389/fdgth.2026.1871353 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Frontiers in Digital Health, online erschienen am 17.11.2026. Verfasst von Bushra Rehan und 2 weiteren Autor:innen. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Incorrect system configuration can compromise medical imaging metadata and disrupt access to diagnostic information.

Objective

To examine the workflow and patient-safety implications of a system time error in an ultrasound device.

Methods

This qualitative case report analysed one anonymised incident from the Swedish ReidarMTP repository using patient-safety and HIT classification, imaging workflow analysis, and a risk–control matrix.

Results

Incorrect system time resulted in inaccurate timestamps on echocardiographic images, hindering retrieval and disrupting workflow. Although no direct patient harm was reported, the retrieval difficulties created a potential risk of delayed access to diagnostic information. The original investigation considered BIOS battery degradation the most probable technical explanation but did not independently confirm it; unintended manual alteration of the system date/time remained an alternative hypothesis. The incident also highlighted gaps in routine time verification, administrative access controls, and automated alerts.

Conclusion

This case demonstrates how a technical timekeeping failure can compromise metadata integrity and create downstream patient-safety risks. The contribution lies in integrating incident classification, workflow mapping, and risk–control analysis to connect a technical failure with its operational consequences and potential safeguards.

Zitieren

APA

Rehan, B., Hassoun, A., & Jabin, M. S. R. (2026). Diagnostic delays and data integrity risks in medical imaging systems: a qualitative case report using incident classification and risk–control analysis. Frontiers in Digital Health, 8. https://doi.org/10.3389/fdgth.2026.1871353

Vancouver

Rehan B, Hassoun A, Jabin MSR. Diagnostic delays and data integrity risks in medical imaging systems: a qualitative case report using incident classification and risk–control analysis. Frontiers in Digital Health. 2026;8. doi:10.3389/fdgth.2026.1871353

BibTeX
@article{Rehan2026,
  author = {Rehan, Bushra and Hassoun, Abdallah and Jabin, Md Shafiqur Rahman},
  title = {Diagnostic delays and data integrity risks in medical imaging systems: a qualitative case report using incident classification and risk–control analysis},
  journal = {Frontiers in Digital Health},
  year = {2026},
  volume = {8},
  doi = {10.3389/fdgth.2026.1871353}
}
Kostenlos starten →