EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A calibration method for smartphone camera photophlethysmography

Yinan Xuan, Colin Barry, Nick Antipa, Edward Jay Wang

Frontiers in Digital Health · 24.11.2023 · 5

DOI: 10.3389/fdgth.2023.1301019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Digital Health, online erschienen am 24.11.2023. Verfasst von Yinan Xuan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Electrical and Computer Engineering, UC San Diego, La Jolla, CA, United States. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Smartphone camera photoplethysmography (cPPG) enables non-invasive pulse oximetry and hemoglobin concentration measurements. However, the aesthetic-driven non-linearity in default image capture and preprocessing pipelines poses challenges for consistency and transferability of cPPG across devices. This work identifies two key parameters—tone mapping and sensor threshold—that significantly impact cPPG measurements. We propose a novel calibration method to linearize camera measurements, thus enhancing consistency and transferability of cPPG across devices. A benchtop calibration system is also presented, leveraging a microcontroller and LED setup to characterize these parameters for each phone model. Our validation studies demonstrate that, with appropriate calibration and camera settings, cPPG applications can achieve 74% higher accuracy than with default settings. Moreover, our calibration method proves effective across different smartphone models ( N = 4 ), and calibrations performed on one phone can be applied to other smartphones of the same model ( N = 6 ), enhancing consistency and scalability of cPPG applications.

Schlagwörter

Stichwörter der Autor:innen

calibrationcamerahemoglobinphotoplethysmographypulse oximetrysmartphone

Autor:innen und Institutionen

  • Electrical and Computer Engineering, UC San Diego, La Jolla, CA, United States.
  • The Design Lab, UC San Diego, La Jolla, CA, USA.

Zitieren

APA

Xuan, Y., Barry, C., Antipa, N., & Wang, E. J. (2023). A calibration method for smartphone camera photophlethysmography. Frontiers in Digital Health, 5. https://doi.org/10.3389/fdgth.2023.1301019

Vancouver

Xuan Y, Barry C, Antipa N, Wang EJ. A calibration method for smartphone camera photophlethysmography. Frontiers in Digital Health. 2023;5. doi:10.3389/fdgth.2023.1301019

BibTeX
@article{Xuan2023,
  author = {Xuan, Yinan and Barry, Colin and Antipa, Nick and Wang, Edward Jay},
  title = {A calibration method for smartphone camera photophlethysmography},
  journal = {Frontiers in Digital Health},
  year = {2023},
  volume = {5},
  doi = {10.3389/fdgth.2023.1301019}
}
Kostenlos starten →