EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sealed (zero gas flow) RPCs — a new operational paradigm for gaseous detectors

Alberto Blanco, Paulo Fonte, Luis Lopes, Mario Pimenta

Frontiers in Detector Science and Technology · 17.07.2026 · 4

DOI: 10.3389/fdest.2026.1864641 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Detector Science and Technology, online erschienen am 17.07.2026. Verfasst von Alberto Blanco und 3 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e a Tecnologia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Resistive Plate Chambers (RPCs) are gaseous detectors widely used in High Energy Physics due to their excellent timing performance, high efficiency, scalability, and affordability. However, their operation relies on gas mixtures based on hydrofluorocarbons (HFCs), whose high Global Warming Potential and progressive phase-out under current environmental regulations pose significant challenges for the long-term sustainability of RPC technology. In this work, we investigate a conceptually different approach, as an alternative to eco gas-mixture substitution strategies, based on sealed RPCs, in which the detector is filled with standard gas during assembly and subsequently hermetically sealed, allowing operation without any external gas supply. This approach drastically reduces gas consumption, eliminates the need for complex gas systems, and offers a potential solution compatible with both environmental constraints and high-performance operation. Two sealed RPC configurations, with active areas of approximately 0.1 m 2 and 1 m 2 , have been developed and characterized using atmospheric cosmic muons. The 0.1 m 2 module demonstrates stable operation over an extended period of nearly two continuous years, with an average efficiency of about 98% and low streamer probability. The 1 m 2 prototype exhibits a comparable initial response, although limitations related to mechanical stability are observed. These results demonstrate the feasibility of sealed RPC technology for trigger applications and highlight its potential as a robust, cost-effective, and environmentally sustainable alternative for future gaseous detector systems.

Förderung

  • Fundação para a Ciência e a Tecnologia

Zitieren

APA

Blanco, A., Fonte, P., Lopes, L., & Pimenta, M. (2026). Sealed (zero gas flow) RPCs — a new operational paradigm for gaseous detectors. Frontiers in Detector Science and Technology, 4. https://doi.org/10.3389/fdest.2026.1864641

Vancouver

Blanco A, Fonte P, Lopes L, Pimenta M. Sealed (zero gas flow) RPCs — a new operational paradigm for gaseous detectors. Frontiers in Detector Science and Technology. 2026;4. doi:10.3389/fdest.2026.1864641

BibTeX
@article{Blanco2026,
  author = {Blanco, Alberto and Fonte, Paulo and Lopes, Luis and Pimenta, Mario},
  title = {Sealed (zero gas flow) RPCs — a new operational paradigm for gaseous detectors},
  journal = {Frontiers in Detector Science and Technology},
  year = {2026},
  volume = {4},
  doi = {10.3389/fdest.2026.1864641}
}
Kostenlos starten →