EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High rate MRPC technology for TOF systems and beyond

Kai Sun, Shihao Zhang, Yi Wang

Frontiers in Detector Science and Technology · 11.06.2026 · 4

DOI: 10.3389/fdest.2026.1826588 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Detector Science and Technology, online erschienen am 11.06.2026. Verfasst von Kai Sun und 2 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Ministry of Science and Technology of the People’s Republic of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multi-gap resistive plate chamber (MRPC) technology has become one of the most important detector solutions for time-of-flight (TOF) systems because of their good time resolution, high efficiency, suitability for constructing large-area TOF walls by tiling many modules, and relatively low cost. However, with the increase in accelerator luminosity and event rate, traditional float-glass MRPCs face challenges under high particle flux, including rate-induced voltage drop on resistive plate electrodes, gas contamination and aging, and local instability around spacer regions. These effects directly limit the rate capability, long-term stability, and time resolution of MRPC detectors in TOF system. We summarize recent progress in high rate MRPC technology on three main optimization directions. The first is resistive plate electrode optimization using low resistive glass. This reduces the average voltage drop under irradiation, allowing the detector to maintain an efficiency above 90 % and a time resolution better than 80 p s at particle fluxes up to 60 k H z / c m 2 . The second is gas flow and exchange optimization using sealed MRPC structures. This design reduces the internal gas volume by a factor of about 50 and enables stable operation at a low gas flow rate of 1 m l / m i n , effectively mitigating gas-related aging effects. The third is spacer-related optimization using improved spacer designs like pad spacers and thermal-bonding spacers. These designs decrease the local electric-field distortion by more than a factor of three and reduce the noise rate by two orders of magnitude, significantly improving long-term stability. Experimental results from beam tests and X-ray tests show that these optimization directions are effective and complementary. These developments provide a practical technological route for MRPC detectors operating in high particle flux experiments such as CBM-TOF.

Förderung

  • National Natural Science Foundation of China
  • Ministry of Science and Technology of the People’s Republic of China

Zitieren

APA

Sun, K., Zhang, S., & Wang, Y. (2026). High rate MRPC technology for TOF systems and beyond. Frontiers in Detector Science and Technology, 4. https://doi.org/10.3389/fdest.2026.1826588

Vancouver

Sun K, Zhang S, Wang Y. High rate MRPC technology for TOF systems and beyond. Frontiers in Detector Science and Technology. 2026;4. doi:10.3389/fdest.2026.1826588

BibTeX
@article{Sun2026,
  author = {Sun, Kai and Zhang, Shihao and Wang, Yi},
  title = {High rate MRPC technology for TOF systems and beyond},
  journal = {Frontiers in Detector Science and Technology},
  year = {2026},
  volume = {4},
  doi = {10.3389/fdest.2026.1826588}
}
Kostenlos starten →