EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and performance of the ARIADNE+ detector, bringing novel 3D optical dual-phase LArTPCs to the large scale

Pablo Amedo Martinez, Alexander Deisting, Heriques Frandini Gatti, Diego González-Díaz, Adam John Lowe, Krishanu Majumdar, Konstantinos Mavrokoridis, Marzio Nessi, Barney Philippou, Francesco Pietropaolo, Sudikshan Ravinthiran, Filippo Resnati und 4 weitere

Frontiers in Detector Science and Technology · 2025

DOI: 10.3389/fdest.2025.1593087 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Detector Science and Technology, 2025. Verfasst von Pablo Amedo Martinez und 15 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Facilities Council, European Research Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The ARIADNE programme is focused on the development of a scalable optical readout system for use in future ktonne LAr neutrino experiments, providing high tracking capability and low energy thresholds. Following demonstration at the 1 tonne scale (ARIADNE detector), a 20 tonne experiment has been performed at the CERN Neutrino Platform ( ARIADNE + ) to test scalability for integration into colossal future experiments such as those planned within the DUNE programme. This paper details the design, construction and performance of a 2.3 × 2.3 m light readout plane (LRP), which contained the largest glass THGEM array ever constructed. Four Timepix3 cameras were mounted externally to image the secondary scintillation light produced within the THGEM holes; three cameras operated with a visible image intensifier, and one with a VUV sensitive intensifier coupled to a custom magnesium fluoride lens. The Timepix3 data are natively zero suppressed, and with the 1.6 ns timing resolution, straightforward 3D event reconstruction is possible. A gallery of reconstructed LAr interactions is presented. Energy resolution and calibration were determined using cosmic muons. The energy resolution was found to be approximately 11% for the presented dataset. An outlook on the next steps for this work is given.

Förderung

  • Science and Technology Facilities Council
  • European Research Council

Zitieren

APA

Martinez, P. A., Deisting, A., Gatti, H. F., González-Díaz, D., Lowe, A. J., Majumdar, K., Mavrokoridis, K., Nessi, M., Philippou, B., Pietropaolo, F., Ravinthiran, S., Resnati, F., Roberts, A., Hernández, A. S., Touramanis, C., & Vann, J. (2025). Design and performance of the ARIADNE+ detector, bringing novel 3D optical dual-phase LArTPCs to the large scale. Frontiers in Detector Science and Technology. https://doi.org/10.3389/fdest.2025.1593087

Vancouver

Martinez PA, Deisting A, Gatti HF, González-Díaz D, Lowe AJ, Majumdar K, et al. Design and performance of the ARIADNE+ detector, bringing novel 3D optical dual-phase LArTPCs to the large scale. Frontiers in Detector Science and Technology. 2025. doi:10.3389/fdest.2025.1593087

BibTeX
@article{Martinez2025,
  author = {Martinez, Pablo Amedo and Deisting, Alexander and Gatti, Heriques Frandini and González-Díaz, Diego and Lowe, Adam John and Majumdar, Krishanu and Mavrokoridis, Konstantinos and Nessi, Marzio and Philippou, Barney and Pietropaolo, Francesco and Ravinthiran, Sudikshan and Resnati, Filippo and Roberts, Adam and Hernández, Angela Saá and Touramanis, Christos and Vann, Jared},
  title = {Design and performance of the ARIADNE+ detector, bringing novel 3D optical dual-phase LArTPCs to the large scale},
  journal = {Frontiers in Detector Science and Technology},
  year = {2025},
  doi = {10.3389/fdest.2025.1593087}
}
Kostenlos starten →