Primary and secondary scintillation of CF4-based mixtures in low-pressure gaseous detectors
Frontiers in Detector Science and Technology · 2025
DOI: 10.3389/fdest.2025.1561739 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Detector Science and Technology, 2025. Verfasst von F. M. Brunbauer und 16 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Optical readout of micro-pattern gaseous detectors relies on recording scintillation light emitted during electron avalanche multiplication with imaging sensors of high-granularity pixelated readout. It can be used in applications such as optical Time Projection Chambers for track reconstruction, low material budget beam monitoring or radiography, to name but a few. A good match between the scintillation light emission spectra and the spectral sensitivity of the recording devices is required to achieve high signal-to-noise ratios and ensure optimal acquisition parameters. Experimental requirements for operation at low or high pressures may have an impact on the scintillation spectra of gases commonly used for optical readout. We investigate the pressure dependence of scintillation light emission spectra of primary and secondary scintillation in the range of 1,000 mbar down to 25 mbar, in the wavelength range of 200 nm–800 nm. Primary scintillation spectra for different CF4-based mixtures are observed to be independent of pressure in the investigated range. A strong variation in the ratio of ultraviolet (UV) emission to visible (VIS) emission bands is observed as a function of pressure for secondary scintillation of CF 4 and He/ CF 4 mixtures while for Ar/ CF 4 the overall light yield varies with an almost constant ratio between UV and VIS components. While the addition of low fractions of SF 6 as electronegative drift gas does significantly lower the total light output, the shape of the emission spectra is not affected. The observed increase in relative UV emission for low pressure operation in CF 4 and He/ CF 4 mixtures can guide the selection of optical readout devices or wavelength shifters for applications requiring low gas pressure operation.
Zitieren
APA
Brunbauer, F. M., Amedo, P., Flöthner, K. J., Diaz, D. G., Janssens, D., Leardini, S., Lisowska, M., Müller, H., Oliveri, E., Orlandini, G., Pfeiffer, D., Ropelewski, L., Sauli, F., Samarati, J., Scharenberg, L., Stenis, M. V., & Veenhof, R. (2025). Primary and secondary scintillation of CF4-based mixtures in low-pressure gaseous detectors. Frontiers in Detector Science and Technology. https://doi.org/10.3389/fdest.2025.1561739
Vancouver
Brunbauer FM, Amedo P, Flöthner KJ, Diaz DG, Janssens D, Leardini S, et al. Primary and secondary scintillation of CF4-based mixtures in low-pressure gaseous detectors. Frontiers in Detector Science and Technology. 2025. doi:10.3389/fdest.2025.1561739
BibTeX
@article{Brunbauer2025,
author = {Brunbauer, F. M. and Amedo, P. and Flöthner, K. J. and Diaz, D. Gonzalez and Janssens, D. and Leardini, S. and Lisowska, M. and Müller, H. and Oliveri, E. and Orlandini, G. and Pfeiffer, D. and Ropelewski, L. and Sauli, F. and Samarati, J. and Scharenberg, L. and Stenis, M. van and Veenhof, R.},
title = {Primary and secondary scintillation of CF4-based mixtures in low-pressure gaseous detectors},
journal = {Frontiers in Detector Science and Technology},
year = {2025},
doi = {10.3389/fdest.2025.1561739}
}
EUVIMED