Case Report: The mystery of a wide-QRS complex tachycardia with a competitive pacing rhythm: device malfunction?
Frontiers in Cardiovascular Medicine · 24.11.2026 · 13
DOI: 10.3389/fcvm.2026.1967110 ↗Kurz gefasst
Fallbericht in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 24.11.2026. Verfasst von Xianchao Sun und 2 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The diagnostic dilemma that arises when automated device pacing algorithms interact with a wide-QRS tachycardia in a patient with an implanted cardiac device is highlighted by this case report. We report a 60-year-old male patient with Fabry disease complicated by hypertrophic cardiomyopathy, who had undergone primary prevention implantation of a dual-chamber transvenous implantable cardioverter-defibrillator (ICD; Boston Scientific, model D142). He presented to the emergency department with palpitations for 1.5 h, and the 12-lead ECG recorded a wide-QRS complex tachycardia with a pacing rhythm. Through device interrogation (live real-time interrogation), with real-time intracardiac electrogram marker channel display and confirmation by a retrospective review of stored electrograms, the arrhythmia was diagnosed as atrial flutter, ventricular tachycardia (VT), and operation of the special ventricular rate regulation function. We subsequently modified the device programming and lowered the VT detection rate to 140 beats/min, which triggered the programmed therapy in the VT zone, namely antitachycardia pacing therapy and ICD shock therapy, terminating both the ventricular tachycardia and the atrial flutter. This case demonstrates that when slow-rate ventricular tachycardia coexists with a pacing rhythm, a concomitant rapid atrial arrhythmia should be considered; device interrogation, when necessary, can prevent device malfunction.
Zitieren
APA
Sun, X., Wang, Q., & Wang, L. (2026). Case Report: The mystery of a wide-QRS complex tachycardia with a competitive pacing rhythm: device malfunction?. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1967110
Vancouver
Sun X, Wang Q, Wang L. Case Report: The mystery of a wide-QRS complex tachycardia with a competitive pacing rhythm: device malfunction?. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1967110
BibTeX
@article{Sun2026,
author = {Sun, Xianchao and Wang, Qingcheng and Wang, Linhua},
title = {Case Report: The mystery of a wide-QRS complex tachycardia with a competitive pacing rhythm: device malfunction?},
journal = {Frontiers in Cardiovascular Medicine},
year = {2026},
volume = {13},
doi = {10.3389/fcvm.2026.1967110}
}