Case Report: Clinical application of an adjustable curved sheath in retrieval of difficult-to-retrieve inferior vena cava filters: a retrospective case series
Frontiers in Cardiovascular Medicine · 24.11.2026 · 13
DOI: 10.3389/fcvm.2026.1900623 ↗Kurz gefasst
Fallbericht in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 24.11.2026. Verfasst von Qiang Zhang und 6 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
To investigate technique and application outcomes of the Fustar adjustable curved sheath in the retrieval of difficult-to-retrieve inferior vena cava (IVC) filters. Case presentation The clinical data of 12 patients, whose difficult-to-retrieve IVC filters were removed using the Fustar adjustable curved sheath with a snare in The Suzhou Hospital of Traditional Chinese Medicine, were retrospectively analyzed. The IVC filters were successfully removed in all 12 patients. Of them, 9 patients had adherence of the retrieval hooks of filters to the venous wall, and 3 patients had greater than 60° angle of left iliac vein. The straight retrieval catheter initially failed to retrieve the filter in 8 patients, after which the adjustable curved sheath was successfully used to retrieve the filters. In the other 4 patients, the adjustable curved sheath was applied as first choice and successfully retrieved the difficult-to-retrieve IVC filters. Thrombus was found in 5 of the retrieved IVC filters as well as relatively large amount of thrombus in 2 of the adjustable curved sheaths, which was aspirated out with a syringe. All retrieved 12 filters were intact, without fracture or deformation.
Conclusion
This study showed that the adjustable curved sheath is a feasible option for the retrieval of difficult-to-retrieve IVC filters with relatively simple operational procedure. It has a particularly good application prospect in the retrieval of filters with retrieval hooks that are tilted against the vessel wall.
Zitieren
APA
Zhang, Q., Zheng, G., Li, Y., Li, C., Pan, Z., Shi, S., & Rong, J. (2026). Case Report: Clinical application of an adjustable curved sheath in retrieval of difficult-to-retrieve inferior vena cava filters: a retrospective case series. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1900623
Vancouver
Zhang Q, Zheng G, Li Y, Li C, Pan Z, Shi S, et al. Case Report: Clinical application of an adjustable curved sheath in retrieval of difficult-to-retrieve inferior vena cava filters: a retrospective case series. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1900623
BibTeX
@article{Zhang2026,
author = {Zhang, Qiang and Zheng, Guangfeng and Li, Yang and Li, Chuanyong and Pan, Zhichang and Shi, Shuming and Rong, Jianjie},
title = {Case Report: Clinical application of an adjustable curved sheath in retrieval of difficult-to-retrieve inferior vena cava filters: a retrospective case series},
journal = {Frontiers in Cardiovascular Medicine},
year = {2026},
volume = {13},
doi = {10.3389/fcvm.2026.1900623}
}
EUVIMED