EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Real-time CMR combined with cardiopulmonary exercise testing enables integrated assessment of cardiac function during exercise

Lena Maria Röwer, Duy Tam Vu, Mohamed Ali Goundi, Halima Malik, Pablo Emilio Verde, Dirk Voit, Jens Frahm, Anja Müller-Lutz, Gerald Antoch, Michael Steinmetz, Christian Meierhofer, Dirk Klee und 1 weitere

Frontiers in Cardiovascular Medicine · 11.08.2026 · 13

DOI: 10.3389/fcvm.2026.1873004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 11.08.2026. Verfasst von Lena Maria Röwer und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich Heine University Düsseldorf, Düss…. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Heinrich-Heine-Universität Düsseldorf.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cardiopulmonary exercise testing (CPET) is the gold standard for assessing cardiopulmonary responses to physical stress. Real-time magnetic resonance imaging (RT-MRI) enables continuous cardiovascular imaging during free breathing (FB) and dynamic exercise.

Objective

This study aimed to develop a clinically applicable, easy-to-use MR-CPET protocol using user-friendly postprocessing software and to describe preliminary physiological observations in healthy subjects, forming the basis for future clinical applications. Material and Methods Healthy adults ( n = 12) underwent conventional cine cardiac magnetic resonance imaging (CMR) and cardiac RT-MRI at rest and during submaximal exercise in a 1.5 T MR scanner. The protocol included short-axis cine imaging for volumetry and phase-contrast imaging for aortic flow quantification. CPET was performed using an MR-compatible spirometry and a supine exercise setup enabling continuous measurement of respiratory airflow and gas exchange during image acquisition and simultaneous exercise. Data processing included automated spirometry analysis, temporal synchronization with RT-MRI, and ECG- and respiratory-based binning for volumetric reconstruction. Indexed oxygen consumption (VO₂i) and cardiac index (CI) were used to calculate the arteriovenous oxygen difference (a-vO 2 diff) according to the Fick equation. Participant comfort was assessed.

Results

The examination was well tolerated, with only minor discomfort related to the spirometry mask. RT-MRI showed strong agreement with conventional cine MRI for left ventricular volumes and ejection fraction at rest. Submaximal exercise significantly increased heart rate and ventilation, with concomitant increases in VO 2 i (201- 309 mL/min/m 2 ) and CI (3.38- 4.24 L/min/m 2 ), while ventricular volumes slightly decreased and ejection fraction remained unchanged. The calculated a-vO 2 diff increased from 5.9 to 7.3 mL/dL, indicating enhanced peripheral oxygen extraction. Data conclusion Combined CPET and cardiac RT-MRI using the presented user- and participant-friendly setup enables integrated assessment of cardiopulmonary performance and cardiovascular function during submaximal exercise and provides physiologically plausible Fick-derived measures of oxygen transport and utilization.

Schlagwörter

Stichwörter der Autor:innen

Fick principleMR-CPETcardiac functioncardiac magnetic resonance (CMR) imagingcardiopulmonary exercise testing (CPET)cardiovascular MRIimage processing computer-assistedreal-time MRI

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital Düsseldorf, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
  • Coordination Centre for Clinical Trials, University Hospital Düsseldorf, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
  • Max Planck Institute for Multidisciplinary Sciences, Göttingen, Germany.
  • Biomedical Physics, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
  • CARID, Cardiovascular Research Institute Düsseldorf, University Hospital Düsseldorf, Heinrich Heine University, Düsseldorf, Germany.
  • Department of Pediatric Cardiology and Intensive Care Medicine, University Medical Center, Georg-August-University, Goettingen, Germany.

Förderung

  • Heinrich-Heine-Universität Düsseldorf

Zitieren

APA

Röwer, L. M., Vu, D. T., Goundi, M. A., Malik, H., Verde, P. E., Voit, D., Frahm, J., Müller-Lutz, A., Antoch, G., Steinmetz, M., Meierhofer, C., Klee, D., & Pillekamp, F. (2026). Real-time CMR combined with cardiopulmonary exercise testing enables integrated assessment of cardiac function during exercise. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1873004

Vancouver

Röwer LM, Vu DT, Goundi MA, Malik H, Verde PE, Voit D, et al. Real-time CMR combined with cardiopulmonary exercise testing enables integrated assessment of cardiac function during exercise. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1873004

BibTeX
@article{Rwer2026,
  author = {Röwer, Lena Maria and Vu, Duy Tam and Goundi, Mohamed Ali and Malik, Halima and Verde, Pablo Emilio and Voit, Dirk and Frahm, Jens and Müller-Lutz, Anja and Antoch, Gerald and Steinmetz, Michael and Meierhofer, Christian and Klee, Dirk and Pillekamp, Frank},
  title = {Real-time CMR combined with cardiopulmonary exercise testing enables integrated assessment of cardiac function during exercise},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fcvm.2026.1873004}
}
Kostenlos starten →