EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

On the redundancy of denoising in electrocardiogram reconstruction

Ekenedirichukwu N Obianom, Abdulhamed M Jasim, Abubakar Sadiq Muhammad, G André Ng, Xin Li

Frontiers in Cardiovascular Medicine · 26.06.2026 · 13

DOI: 10.3389/fcvm.2026.1827352 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 26.06.2026. Verfasst von Ekenedirichukwu N Obianom und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiovascular Sciences, University of Leicester, Leicester, United Kingdom. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Electrocardiogram (ECG) reconstruction involves synthesizing specific leads from other recorded leads, addressing cases where standard ECGs have missing, noisy, or unrecorded leads. Traditionally, reconstruction pipelines include a denoising step, which could be time-consuming and may distort the original signal morphology. Recent studies have shown that reconstruction can be successfully performed without denoising by using multiple models tailored to different input noise levels. This paper builds on that approach by evaluating whether a single, unified model can achieve similar performance.

Methods

The study compares the multiple-model pipeline (MMP) and the single-model pipeline (SMP) using 10,000 normal ECG records from the CODE-15% database (trimmed to 10 s, resampled to 500 Hz, and denoised to act as a reference point for when artificial noise is added prior to reconstruction).

Results

Results show that the SMP performs comparably to the MMP, achieving average correlations above 0.85, consistent with previous research, and maintaining stable performance across noise levels (∼0.04 variation). Although the model performs poorly when tested on abnormal ECG, fine-tuning the model through transfer learning with as little as ten seconds data returns its performance to the expected level by making the generic model patient specific.

Discussion

These findings have significant implications for wearable medical devices, where minimizing storage and computational demands is critical. While the MMP requires over five times the memory due to multiple models, the SMP (and transfer learning) offers a more streamlined, efficient, and cost-effective solution by eliminating both the need for multiple models and separate denoising steps.

Schlagwörter

Stichwörter der Autor:innen

ECGLSTMcorrelationdenoisingmachine learningreconstructiontransfer learning

Autor:innen und Institutionen

  • Division of Cardiovascular Sciences, University of Leicester, Leicester, United Kingdom.
  • School of Engineering, University of Leicester, Leicester, United Kingdom.
  • Department of Cardiology, University Hospitals of Leicester NHS Trust, Leicester, United Kingdom.
  • Leicester British Heart Foundation Centre of Research Excellence, Leicester, United Kingdom.
  • Leicester National Institute for Health and Care Research Biomedical Research Centre, Leicester, United Kingdom.

Förderung

  • Medical Research Council

Zitieren

APA

Obianom, E. N., Jasim, A. M., Muhammad, A. S., Ng, G. A., & Li, X. (2026). On the redundancy of denoising in electrocardiogram reconstruction. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1827352

Vancouver

Obianom EN, Jasim AM, Muhammad AS, Ng GA, Li X. On the redundancy of denoising in electrocardiogram reconstruction. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1827352

BibTeX
@article{Obianom2026,
  author = {Obianom, Ekenedirichukwu N and Jasim, Abdulhamed M and Muhammad, Abubakar Sadiq and Ng, G André and Li, Xin},
  title = {On the redundancy of denoising in electrocardiogram reconstruction},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fcvm.2026.1827352}
}
Kostenlos starten →