A comparison of sequential density ultracentrifugation and density gradient ultracentrifugation for the proteomic analysis of high-density lipoprotein
Frontiers in Cardiovascular Medicine · 15.05.2026 · 13
DOI: 10.3389/fcvm.2026.1817349 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 15.05.2026. Verfasst von Jack D Beazer und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Cardiovascular and Metabolic Health, Glasgow Cardiovascular Research Centre, University of Glasgow, Glasgow, United Kingdom. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Heart Foundation.
Abstract (Originalsprache)
Introduction
With the failure of high-density lipoprotein (HDL) cholesterol raising therapies to reduce cardiovascular risk, attention has turned towards HDL composition and function. There are several techniques for the isolation of lipoproteins from plasma, with density ultracentrifugation considered the gold-standard method. It is not known which form of density ultracentrifugation is optimal for HDL composition and function analyses.
Methods
This study compared HDL composition by nLC-MS/MS and ELISA, subclass distribution by gel electrophoresis, and in vitro vascular anti-inflammatory function in HDL fractions isolated by sodium bromide sequential density ultracentrifugation (SDU) and iodixanol density gradient ultracentrifugation (DGU).
Results
HDL composition differed between the two isolation techniques, with DGU-isolated HDL fractions containing a higher total protein content than SDU (10.14 ± 1.49 mg/mL compared to 3.18 ± 1.10 mg/mL respectively, p < 0.001, mean ± SD) but lower proteomic detection of key HDL proteins such as apolipoprotein A-I, apolipoprotein A-II and paraoxonase-1 in DGU-isolated HDL. HDL subclass distribution could not be determined in DGU HDL fractions due to contaminating plasma proteins. Vascular anti-inflammatory function was higher in DGU HDL (77.5 ± 4.4 % compared to 58.3 ± 4.8%, mean ± SD, p = 0.014) possibly due to the presence of confounding plasma proteins.
Conclusion
Further steps may need to be added to DGU methods to obtain a ‘cleaner’ HDL fraction and therefore currently SDU is better suited to studies of HDL composition and function.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Cardiovascular and Metabolic Health, Glasgow Cardiovascular Research Centre, University of Glasgow, Glasgow, United Kingdom.
- Occupational and Environmental Medicine Center in Linköping, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
- Research Institute of Sport and Exercise Science, Liverpool John Moores University, Liverpool, United Kingdom.
Förderung
- British Heart Foundation
Zitieren
APA
Beazer, J. D., Ljunggren, S., Karlsson, H., Davies, I. G., & Freeman, D. J. (2026). A comparison of sequential density ultracentrifugation and density gradient ultracentrifugation for the proteomic analysis of high-density lipoprotein. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1817349
Vancouver
Beazer JD, Ljunggren S, Karlsson H, Davies IG, Freeman DJ. A comparison of sequential density ultracentrifugation and density gradient ultracentrifugation for the proteomic analysis of high-density lipoprotein. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1817349
BibTeX
@article{Beazer2026,
author = {Beazer, Jack D and Ljunggren, Stefan and Karlsson, Helen and Davies, Ian G and Freeman, Dilys J},
title = {A comparison of sequential density ultracentrifugation and density gradient ultracentrifugation for the proteomic analysis of high-density lipoprotein},
journal = {Frontiers in Cardiovascular Medicine},
year = {2026},
volume = {13},
doi = {10.3389/fcvm.2026.1817349}
}
EUVIMED