EUVIMEDEUVIMED entdecken
Fall-Kontroll-StudieOpen Access · CC BY 4.0

Radiation-associated bioprosthetic valve dysfunction: an initial case-control analysis

Ioana Petrescu, Atif M Islam, Brian Blair, Bibhu D Mohanty

Frontiers in Cardiovascular Medicine · 19.06.2026 · 13

DOI: 10.3389/fcvm.2026.1783103 ↗

Kurz gefasst

Fall-Kontroll-Studie in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 19.06.2026. Verfasst von Ioana Petrescu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, West Virginia University, Morgantown, WV, United States. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Radiation therapy (RT) for intrathoracic and breast malignancies has been associated with long-term valvular heart disease (VHD) in native valves. However, its impact on bioprosthetic heart valves remains unclear. We aimed to assess changes in transvalvular gradients following RT in patients with previously implanted bioprosthetic valves.

Methods

We identified 23 patients who underwent bioprosthetic valve implantation followed by chest RT and compared them with matched controls who did not receive RT. Serial echocardiographic gradients were analyzed post-implantation, pre-RT, and at two intervals post-RT (within 12 months and at 12–24 months). Univariable linear regression was used to evaluate associations between RT dose metrics, timing of RT, and changes in transvalvular gradients.

Results

Transvalvular gradients remained stable in control patients but increased significantly over time in the RT group (Friedman's test P < 0.0001). Both total RT dose and mean heart RT dose significantly predicted increases in transvalvular gradients within 12 months (R² = 0.41, P = 0.001) and between 12 and 24 months (R² = 0.62, P < 0.0001) of RT completion. Shorter time between valve implantation and RT also predicted greater gradient increases. No patients required re-intervention during the follow-up period.

Conclusion

Chest RT is associated with early, dose-dependent elevations in transvalvular gradients among patients with bioprosthetic valves. Although the observed changes were modest and did not necessitate re-intervention, these findings highlight the need for long-term surveillance and further research to understand the durability of irradiated bioprosthetic valves.

Schlagwörter

Stichwörter der Autor:innen

bioprosthetic valvecardiotoxicityhemodynamicsradiation-associated heart diseaseradiotherapytransvalvular gradientvalve durabilityvalvular heart disease

Autor:innen und Institutionen

  • Department of Cardiology, West Virginia University, Morgantown, WV, United States.
  • Morsani College of Medicine, University of South Florida Morsani College of Medicine, Tampa, FL, United States.
  • Department of Internal Medicine, University of South Florida Morsani College of Medicine, Tampa, FL, United States.
  • Division of Cardiovascular Sciences, University of South Florida Morsani College of Medicine, Tampa, FL, United States.

Zitieren

APA

Petrescu, I., Islam, A. M., Blair, B., & Mohanty, B. D. (2026). Radiation-associated bioprosthetic valve dysfunction: an initial case-control analysis. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1783103

Vancouver

Petrescu I, Islam AM, Blair B, Mohanty BD. Radiation-associated bioprosthetic valve dysfunction: an initial case-control analysis. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1783103

BibTeX
@article{Petrescu2026,
  author = {Petrescu, Ioana and Islam, Atif M and Blair, Brian and Mohanty, Bibhu D},
  title = {Radiation-associated bioprosthetic valve dysfunction: an initial case-control analysis},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fcvm.2026.1783103}
}
Kostenlos starten →