Impact of intracardiac echocardiography on radiofrequency catheter ablation for atrial fibrillation: a clinical study on procedural parameters and post-procedural recurrence
Frontiers in Cardiovascular Medicine · 18.05.2026 · 13
DOI: 10.3389/fcvm.2026.1746680 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 18.05.2026. Verfasst von Feiyue Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: First Clinical Medical College, Qingdao University, Qingdao, China. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
Radiofrequency catheter ablation (RFCA) has become a first-line treatment for atrial fibrillation (AF). Abnormal force-over-time (FOT), a procedural parameter, leads to gaps and influences ablation continuity and transmurality. Intracardiac echocardiography (ICE) provides valuable guidance during RFCA. This retrospective study investigates the impact of ICE on FOT and recurrence in RFCA.
Methods
Propensity score matching (PSM) was performed to mitigate the impact of intergroup imbalance. The Kendall correlation, point-biserial correlation coefficient test and multivariate Gamma regression were employed to analyze factors influencing procedure and ablation time. Univariate and multivariate Cox regression analysis were performed to analyze factors influencing recurrence.
Results
A total of 167 patients were enrolled. After PSM, 102 patients were included with 51 patients in each of the ICE and non-ICE groups. After adjusting for confounding factors, baseline eGFR (HR = 0.97, 95% CI 0.94–0.99, P = 0.017) and high FOT count in RPS segment (HR = 1.48, 95% CI 1.05–2.09, P = 0.025) were independent factors influencing recurrence. The eGFR (RR = 1.005, 95% CI 1.000–1.009, P = 0.038) and low FOT count in LAI segment (RR = 1.019, 95% CI 1.002–1.036, P = 0.033), high FOT count in RPI segment (RR = 0.948, 95% CI 0.902–0.996, P = 0.036) were factors influencing ablation time, while high FOT count in LF segment (RR = 1.072, 95% CI 1.008–1.139, P = 0.029), cardiomyopathy (RR = 2.181, 95% CI 1.339–3.554, P = 0.002), and LAAO (RR = 1.485, 95% CI 1.249–1.766, P < 0.001) were factors influencing procedure time.
Conclusions
ICE influences the distribution of abnormal FOT across PV segments. ICE-guided procedures demonstrated improvement in recurrence. However, the benefits may not be directly provided by ICE but rather mediated through the occurrence of abnormal FOT.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- First Clinical Medical College, Qingdao University, Qingdao, China.
- Department of Cardiology, The Affiliated Hospital of Qingdao University, Qingdao, China.
- Qingdao Medical College, Qingdao University, Qingdao, China.
- Department of Internal Medicine, The Affiliated Hospital of Qingdao University, Qingdao, China.
Zitieren
APA
Liu, F., Wang, M., Jv, Y., Wang, Z., & Cai, S. (2026). Impact of intracardiac echocardiography on radiofrequency catheter ablation for atrial fibrillation: a clinical study on procedural parameters and post-procedural recurrence. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1746680
Vancouver
Liu F, Wang M, Jv Y, Wang Z, Cai S. Impact of intracardiac echocardiography on radiofrequency catheter ablation for atrial fibrillation: a clinical study on procedural parameters and post-procedural recurrence. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1746680
BibTeX
@article{Liu2026,
author = {Liu, Feiyue and Wang, Maojing and Jv, Yuefeng and Wang, Zhihui and Cai, Shanglang},
title = {Impact of intracardiac echocardiography on radiofrequency catheter ablation for atrial fibrillation: a clinical study on procedural parameters and post-procedural recurrence},
journal = {Frontiers in Cardiovascular Medicine},
year = {2026},
volume = {13},
doi = {10.3389/fcvm.2026.1746680}
}
EUVIMED