EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cost-effectiveness of implantable cardioverter-defibrillators for primary prevention in heart failure with reduced ejection fraction: a Markov model using JROAD-DPC cost data in Japan

Kazuki Ohashi, Masaya Watanabe, Yasuhiro Morii, Hisashi Yokoshiki, Kengo Kusano, Katsuhiko Imai, Masahiko Takagi, Teiichi Yamane, Hiroshi Tada, Katsuhiko Ogasawara

Frontiers in Cardiovascular Medicine · 05.03.2026 · 13

DOI: 10.3389/fcvm.2026.1744517 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 05.03.2026. Verfasst von Kazuki Ohashi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Health Sciences, Hokkaido University, Sapporo, Japan. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Implantable cardioverter-defibrillators (ICDs) reduce the risk of sudden cardiac death caused by ventricular tachycardia or ventricular fibrillation in patients with ischemic and non-ischemic cardiomyopathy. However, the cost-effectiveness of ICD implantation in Japanese patients with heart failure and reduced left ventricular ejection fraction remains unclear. This study aimed to evaluate the cost-effectiveness of ICD implantation in a Japanese setting.

Methods

A Markov model with 1-month cycles was developed to assess the cost-effectiveness of ICD implantation compared with conventional medical therapy. The analysis was conducted from the perspective of a public healthcare payer over a 30-year time horizon. Scenario analyses accounting for waning treatment effects were performed, as along with deterministic and probabilistic sensitivity analyses (PSA).

Results

In the base-case analysis, the incremental cost-effectiveness ratio (ICER) was US $29,838 per quality-adjusted life year (QALY). In the scenario analyses, the ICER increased to US $40,205 and $36,199 per QALY when the treatment effect began to wane after 5 and 10 years, respectively. ICD efficacy and battery longevity had the greatest influence on the ICER. PSA showed that the ICER per QALY ranged from US $19,472 at the 2.5th percentile to US $83,365 at the 97.5th percentile.

Conclusions

In the Japanese healthcare context, ICD implantation for primary prevention was found to be more cost-effective than the reference value. However, depending on several assumptions, the ICER may exceed the reference value. Sensitivity analyses highlighted the significant impact of the hazard ratio and battery longevity on cost-effectiveness. Further research is needed to identify subpopulations with significantly different cost-effectiveness outcomes.

Schlagwörter

Stichwörter der Autor:innen

cost-effectiveness analysisimplantable cardioverter-defibrillatorleft ventricular ejection fractionprimary preventionsudden cardiac death

Autor:innen und Institutionen

  • Faculty of Health Sciences, Hokkaido University, Sapporo, Japan.
  • Department of Cardiovascular Medicine, Caress Memorial Hospital, Sapporo, Japan.
  • Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Sapporo, Japan.
  • Center for Outcomes Research and Economic Evaluation for Health, National Institute of Public Health, Wako, Japan.
  • Department of Cardiovascular Medicine Sapporo City General Hospital, Sapporo, Japan.
  • Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center Hospital, Suita, Japan.

Zitieren

APA

Ohashi, K., Watanabe, M., Morii, Y., Yokoshiki, H., Kusano, K., Imai, K., Takagi, M., Yamane, T., Tada, H., & Ogasawara, K. (2026). Cost-effectiveness of implantable cardioverter-defibrillators for primary prevention in heart failure with reduced ejection fraction: a Markov model using JROAD-DPC cost data in Japan. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1744517

Vancouver

Ohashi K, Watanabe M, Morii Y, Yokoshiki H, Kusano K, Imai K, et al. Cost-effectiveness of implantable cardioverter-defibrillators for primary prevention in heart failure with reduced ejection fraction: a Markov model using JROAD-DPC cost data in Japan. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1744517

BibTeX
@article{Ohashi2026,
  author = {Ohashi, Kazuki and Watanabe, Masaya and Morii, Yasuhiro and Yokoshiki, Hisashi and Kusano, Kengo and Imai, Katsuhiko and Takagi, Masahiko and Yamane, Teiichi and Tada, Hiroshi and Ogasawara, Katsuhiko},
  title = {Cost-effectiveness of implantable cardioverter-defibrillators for primary prevention in heart failure with reduced ejection fraction: a Markov model using JROAD-DPC cost data in Japan},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fcvm.2026.1744517}
}
Kostenlos starten →