EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative study on the efficacy and safety of different left atrial appendage occluders in one-stop atrial fibrillation procedures

Haoqing Ren, Hengli Lai

Frontiers in Cardiovascular Medicine · 26.05.2026 · 13

DOI: 10.3389/fcvm.2026.1742519 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 26.05.2026. Verfasst von Haoqing Ren und 1 weiteren Autor:innen. Beteiligte Einrichtung: Jiangxi Medical College, Nanchang University, Nanchang, China. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the sealing efficacy and safety of three left atrial appendage (LAA) occluders—WATCHMAN, LAmbre, and LACBES—in a one-stop procedure combining catheter ablation (CA) and LAA occlusion (LAAO) for atrial fibrillation (AF).

Methods

We retrospectively analyzed 231 AF patients undergoing a one-stop procedure, grouped by implanted occluder (WATCHMAN n = 110, LAmbre n = 72, LACBES n = 49). The 6-month peri-device leak (PDL) was compared across devices, and Firth-corrected logistic regression and Cox proportional hazards models were applied for PDL and stroke analyses, respectively, given low event counts.

Results

Baseline characteristics were comparable across the three groups ( P > 0.05). PDL rates were 8.2% (9/110), 6.9% (5/72), and 4.1% (2/49) for the WATCHMAN, LAmbre, and LACBES groups, respectively, with no statistically significant intergroup differences ( P > 0.05). Multivariate analysis using Firth correction confirmed that device type was not an independent predictor of PDL, after adjusting for clinical risk profiles. However, a higher CHA 2 DS 2 -VASc score was an independent risk factor, whereas older age was a protective factor. No statistically significant differences in DRT or stroke incidence were observed among the devices during the study's follow-up period and with its limited sample size. However, the statistical power for these rare safety endpoints was low, necessitating larger studies to confirm long-term safety comparisons.

Conclusion

In the context of the one-stop AF procedure, the WATCHMAN, LAmbre, and LACBES occluders demonstrated comparable effectiveness in achieving LAA closure. A high CHA 2 DS 2 -VASc score and younger age may be risk factors for PDL, warranting closer monitoring in these patient subgroups.

Schlagwörter

Stichwörter der Autor:innen

atrial fibrillationdevice-related thrombosisleft atrial appendage occlusionoccluderone-stop procedure

Autor:innen und Institutionen

  • Jiangxi Medical College, Nanchang University, Nanchang, China.
  • Department of Cardiology, Jiangxi Provincial People's Hospital, The First Affiliated Hospital of Nanchang Medical College, Nanchang, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Ren, H., & Lai, H. (2026). Comparative study on the efficacy and safety of different left atrial appendage occluders in one-stop atrial fibrillation procedures. Frontiers in Cardiovascular Medicine, 13. https://doi.org/10.3389/fcvm.2026.1742519

Vancouver

Ren H, Lai H. Comparative study on the efficacy and safety of different left atrial appendage occluders in one-stop atrial fibrillation procedures. Frontiers in Cardiovascular Medicine. 2026;13. doi:10.3389/fcvm.2026.1742519

BibTeX
@article{Ren2026,
  author = {Ren, Haoqing and Lai, Hengli},
  title = {Comparative study on the efficacy and safety of different left atrial appendage occluders in one-stop atrial fibrillation procedures},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  volume = {13},
  doi = {10.3389/fcvm.2026.1742519}
}
Kostenlos starten →