EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Phonocardiography based pulse wave velocity system for non-occlusive assessment of arterial stiffness

T Corina Margain, Emily Powell, Alexandra Clark, Adam Bush

Frontiers in Cardiovascular Medicine · 23.01.2025 · 12

DOI: 10.3389/fcvm.2025.1481836 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 23.01.2025. Verfasst von T Corina Margain und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering Department, Translational Cardiovascular Imaging Group, The University of Texas at Austin, Austin, TX, United States. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 80 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Arterial stiffness is strongly associated with vascular aging and pathology and can be assessed in many ways. Existing devices for measuring central arterial stiffness, such as carotid-femoral pulse wave velocity (PWV), are limited by high costs and the need for specialized expertise, limiting widespread clinical adoption. This study introduces a semi- and non-occlusive PWV measurement system using phonocardiography (PCG) and plethysmography (PPG) and a single femoral pressure cuff, aiming to address these limitations. We conducted a study comparing a semi-occlusive (carotid-femoral PWV) and a non-occlusive (carotid-toe PWV) PCG-based PWV measurements across a cohort of 63 volunteers, as compared to literature reference PWV values. Results demonstrated strong correlations between our PCG-based PWV measures (PWV carotid−femoral : 8.42 ± 3.99 m/s vs. PWV carotid−toe : 10.62 ± 3.86 m/s) with age as a significant predictor (PWV carotid−femoral : r 2 = 0.45; PWV carotid−toe : r 2 = 0.28, p < 0.05). Ultrasound measured distensibility assessments confirmed the reliability of our PCG approach in reflecting central arterial stiffness dynamics, particularly at the aortic level. Test–retest reliability analyses yielded high intraclass correlation coefficients (0.75 ≤ ICC ≤ 90), indicating robust repeatability of our method. This study highlights the feasibility and accuracy of our low-cost, semi and non-occlusive PWV measurement systems to enhance accessibility in arterial stiffness assessments, potentially easing cardiovascular risk stratification.

Schlagwörter

Stichwörter der Autor:innen

arterial stiffnesscardiovascular healthphonocardiographyplethysmographypulse wave velocity

Autor:innen und Institutionen

  • Biomedical Engineering Department, Translational Cardiovascular Imaging Group, The University of Texas at Austin, Austin, TX, United States.
  • Mechanisms Underlying Neurocognitive Aging Laboratory, Department of Psychology, The University of Texas at Austin, Austin, TX, United States.

Zitieren

APA

Margain, T. C., Powell, E., Clark, A., & Bush, A. (2025). Phonocardiography based pulse wave velocity system for non-occlusive assessment of arterial stiffness. Frontiers in Cardiovascular Medicine, 12. https://doi.org/10.3389/fcvm.2025.1481836

Vancouver

Margain TC, Powell E, Clark A, Bush A. Phonocardiography based pulse wave velocity system for non-occlusive assessment of arterial stiffness. Frontiers in Cardiovascular Medicine. 2025;12. doi:10.3389/fcvm.2025.1481836

BibTeX
@article{Margain2025,
  author = {Margain, T Corina and Powell, Emily and Clark, Alexandra and Bush, Adam},
  title = {Phonocardiography based pulse wave velocity system for non-occlusive assessment of arterial stiffness},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2025},
  volume = {12},
  doi = {10.3389/fcvm.2025.1481836}
}
Kostenlos starten →