EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access · CC BY 4.0

Diagnostic accuracy of artificial intelligence models in detecting congenital heart disease in the second-trimester fetus through prenatal cardiac screening: a systematic review and meta-analysis

Diagnostische Genauigkeit von KI-Modellen zur Erkennung angeborener Herzfehler im Fetus im zweiten Trimenon durch pränatales kardiales Screening: systematische Übersicht und Metaanalyse

Lies Dina Liastuti, Yosilia Nursakina

Frontiers in Cardiovascular Medicine · 24.02.2025 · 12

DOI: 10.3389/fcvm.2025.1473544 ↗

Auf einen Blick

9 Studien zeigen für KI-Modelle zur Erkennung von angeborenen Herzfehlern im fetalen Zweittrimester eine hohe diagnostische Genauigkeit. Gepoolt lagen Sensitivität, Spezifität und AUC hoch.

Fragestellung

Wie genau erkennen KI-Modelle angeborene Herzfehler im Fetus im zweiten Trimenon beim pränatalen kardialen Screening?

Methode

Systematische Übersicht mit Metaanalyse; Suche in 7 Datenbanken; Bewertung des Verzerrungsrisikos mit QUADAS-AI.

Ergebnisse

9 eingeschlossene Studien. Gepoolte Sensitivität 0,89 (0,81–0,94), Spezifität 0,91 (0,87–0,94) und AUC 0,952 im Random-Effects-Modell.

Einschränkungen

Vor der klinischen Anwendung müssen mehrere Limitationen adressiert werden; prospektive Studien mit größeren Datensätzen und inklusiveren Populationen sind nötig.

Schlussfolgerung der Autor:innen

KI zeigte vielversprechende Ergebnisse bei der Diagnose von angeborenen Herzfehlern, bevor ein Einsatz in der klinischen Praxis möglich ist, sind jedoch weitere Studien nötig.

Kernaussagen

  • 9 Studien wurden in die Metaanalyse eingeschlossen
  • Sensitivität 0,89; Spezifität 0,91
  • AUC 0,952; prospektive Daten fehlen noch

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Systematische Übersicht in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 24.02.2025. Verfasst von Lies Dina Liastuti und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology and Vascular Medicine, Faculty of Medicine Universitas Indonesia, Cipto Mangunkusumo Hospital, Jakarta, Indonesia. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Congenital heart disease (CHD) is a major contributor to morbidity and infant mortality and imposes the highest burden on global healthcare costs. Early diagnosis and prompt treatment of CHD contribute to enhanced neonatal outcomes and survival rates; however, there is a shortage of proficient examiners in remote regions. Artificial intelligence (AI)-powered ultrasound provides a potential solution to improve the diagnostic accuracy of fetal CHD screening.

Methods

A literature search was conducted across seven databases for systematic review. Articles were retrieved based on PRISMA Flow 2020 and inclusion and exclusion criteria. Eligible diagnostic data were further meta-analyzed, and the risk of bias was tested using Quality Assessment of Diagnostic Accuracy Studies—Artificial Intelligence.

Findings

A total of 374 studies were screened for eligibility, but only 9 studies were included. Most studies utilized deep learning models using either ultrasound or echocardiographic images. Overall, the AI models performed exceptionally well in accurately identifying normal and abnormal ultrasound images. A meta-analysis of these nine studies on CHD diagnosis resulted in a pooled sensitivity of 0.89 (0.81–0.94), a specificity of 0.91 (0.87–0.94), and an area under the curve of 0.952 using a random-effects model.

Conclusion

Although several limitations must be addressed before AI models can be implemented in clinical practice, AI has shown promising results in CHD diagnosis. Nevertheless, prospective studies with bigger datasets and more inclusive populations are needed to compare AI algorithms to conventional methods. Systematic Review Registration https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42023461738 , PROSPERO (CRD42023461738).

Schlagwörter

Stichwörter der Autor:innen

artificial intelligencecongenital heart diseasemeta-analysisprenatal cardiac examinationultrasonography

Autor:innen und Institutionen

  • Department of Cardiology and Vascular Medicine, Faculty of Medicine Universitas Indonesia, Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
  • Department of Cardiovascular, Harapan Kita National Heart Center, Jakarta, Indonesia.
  • School of Public Health, Imperial College London, London, United Kingdom.

Zitieren

APA

Liastuti, L. D., & Nursakina, Y. (2025). Diagnostic accuracy of artificial intelligence models in detecting congenital heart disease in the second-trimester fetus through prenatal cardiac screening: a systematic review and meta-analysis. Frontiers in Cardiovascular Medicine, 12. https://doi.org/10.3389/fcvm.2025.1473544

Vancouver

Liastuti LD, Nursakina Y. Diagnostic accuracy of artificial intelligence models in detecting congenital heart disease in the second-trimester fetus through prenatal cardiac screening: a systematic review and meta-analysis. Frontiers in Cardiovascular Medicine. 2025;12. doi:10.3389/fcvm.2025.1473544

BibTeX
@article{Liastuti2025,
  author = {Liastuti, Lies Dina and Nursakina, Yosilia},
  title = {Diagnostic accuracy of artificial intelligence models in detecting congenital heart disease in the second-trimester fetus through prenatal cardiac screening: a systematic review and meta-analysis},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2025},
  volume = {12},
  doi = {10.3389/fcvm.2025.1473544}
}
Kostenlos starten →