EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A hybrid deep image prior and compressed sensing reconstruction method for highly accelerated 3D coronary magnetic resonance angiography

Zhihao Xue, Sicheng Zhu, Fan Yang, Juan Gao, Hao Peng, Chao Zou, Hang Jin, Chenxi Hu

Frontiers in Cardiovascular Medicine · 12.09.2024 · 11

DOI: 10.3389/fcvm.2024.1408351 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 12.09.2024. Verfasst von Zhihao Xue und 7 weiteren Autor:innen. Beteiligte Einrichtung: National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shangha…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

High-resolution whole-heart coronary magnetic resonance angiography (CMRA) often suffers from unreasonably long scan times, rendering imaging acceleration highly desirable. Traditional reconstruction methods used in CMRA rely on either hand-crafted priors or supervised learning models. Although the latter often yield superior reconstruction quality, they require a large amount of training data and memory resources, and may encounter generalization issues when dealing with out-of-distribution datasets.

Methods

To address these challenges, we introduce an unsupervised reconstruction method that combines deep image prior (DIP) with compressed sensing (CS) to accelerate 3D CMRA. This method incorporates a slice-by-slice DIP reconstruction and 3D total variation (TV) regularization, enabling high-quality reconstruction under a significant acceleration while enforcing continuity in the slice direction. We evaluated our method by comparing it to iterative SENSE, CS-TV, CS-wavelet, and other DIP-based variants, using both retrospectively and prospectively undersampled datasets.

Results

The results demonstrate the superiority of our 3D DIP-CS approach, which improved the reconstruction accuracy relative to the other approaches across both datasets. Ablation studies further reveal the benefits of combining DIP with 3D TV regularization, which leads to significant improvements of image quality over pure DIP-based methods. Evaluation of vessel sharpness and image quality scores shows that DIP-CS improves the quality of reformatted coronary arteries.

Discussion

The proposed method enables scan-specific reconstruction of high-quality 3D CMRA from a five-minute acquisition, without relying on fully-sampled training data or placing a heavy burden on memory resources.

Schlagwörter

Stichwörter der Autor:innen

compressed sensingcoronary magnetic resonance angiographydeep image priorimage reconstructionunsupervised learning

Autor:innen und Institutionen

  • National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China.
  • Department of Radiology, Zhongshan Hospital, Fudan University and Shanghai Medical Imaging Institute, Shanghai, China.

Zitieren

APA

Xue, Z., Zhu, S., Yang, F., Gao, J., Peng, H., Zou, C., Jin, H., & Hu, C. (2024). A hybrid deep image prior and compressed sensing reconstruction method for highly accelerated 3D coronary magnetic resonance angiography. Frontiers in Cardiovascular Medicine, 11. https://doi.org/10.3389/fcvm.2024.1408351

Vancouver

Xue Z, Zhu S, Yang F, Gao J, Peng H, Zou C, et al. A hybrid deep image prior and compressed sensing reconstruction method for highly accelerated 3D coronary magnetic resonance angiography. Frontiers in Cardiovascular Medicine. 2024;11. doi:10.3389/fcvm.2024.1408351

BibTeX
@article{Xue2024,
  author = {Xue, Zhihao and Zhu, Sicheng and Yang, Fan and Gao, Juan and Peng, Hao and Zou, Chao and Jin, Hang and Hu, Chenxi},
  title = {A hybrid deep image prior and compressed sensing reconstruction method for highly accelerated 3D coronary magnetic resonance angiography},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2024},
  volume = {11},
  doi = {10.3389/fcvm.2024.1408351}
}
Kostenlos starten →