Virtual calcium removal in calcified coronary arteries with photon-counting detector CT—first in-vivo experience
Frontiers in Cardiovascular Medicine · 22.02.2024 · 11
DOI: 10.3389/fcvm.2024.1367463 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 22.02.2024. Verfasst von Victor Mergen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To evaluate the feasibility and accuracy of quantification of calcified coronary stenoses using virtual non-calcium (VNCa) images in coronary CT angiography (CCTA) with photon-counting detector (PCD) CT compared with quantitative coronary angiography (QCA). Materials and methods This retrospective, institutional-review board approved study included consecutive patients with calcified coronary artery plaques undergoing CCTA with PCD-CT and invasive coronary angiography between July and December 2022. Virtual monoenergetic images (VMI) and VNCa images were reconstructed. Diameter stenoses were quantified on VMI and VNCa images by two readers. 3D-QCA served as the standard of reference. Measurements were compared using Bland-Altman analyses, Wilcoxon tests, and intraclass correlation coefficients (ICC).
Results
Thirty patients [mean age, 64 years ± 8 (standard deviation); 26 men] with 81 coronary stenoses from calcified plaques were included. Ten of the 81 stenoses (12%) had to be excluded because of erroneous plaque subtraction on VNCa images. Median diameter stenosis determined on 3D-QCA was 22% (interquartile range, 11%–35%; total range, 4%–88%). As compared with 3D-QCA, VMI overestimated diameter stenoses (mean differences −10%, p < .001, ICC: .87 and −7%, p < .001, ICC: .84 for reader 1 and 2, respectively), whereas VNCa images showed similar diameter stenoses (mean differences 0%, p = .68, ICC: .94 and 1%, p = .07, ICC: .93 for reader 1 and 2, respectively).
Conclusion
First experience in mainly minimal to moderate stenoses suggests that virtual calcium removal in CCTA with PCD-CT, when feasible, has the potential to improve the quantification of calcified stenoses.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
- Monaco Cardiothoracic Center, Monaco, Monaco.
- Department of Diagnostic and Interventional Radiology, All India Institute of Medical Sciences, Jodhpur, India.
- Department of Radiology, La Fe University and Polytechnic Hospital, Valencia, Spain.
- Department of Cardiology, University Heart Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
- Institute of Radiology, Spitäler fmi AG, Spital Interlaken, Unterseen, Switzerland.
Zitieren
APA
Mergen, V., Rusek, S., Civaia, F., Rossi, P., Rajagopal, R., Bättig, E., Manka, R., Candreva, A., Eberhard, M., & Alkadhi, H. (2024). Virtual calcium removal in calcified coronary arteries with photon-counting detector CT—first in-vivo experience. Frontiers in Cardiovascular Medicine, 11. https://doi.org/10.3389/fcvm.2024.1367463
Vancouver
Mergen V, Rusek S, Civaia F, Rossi P, Rajagopal R, Bättig E, et al. Virtual calcium removal in calcified coronary arteries with photon-counting detector CT—first in-vivo experience. Frontiers in Cardiovascular Medicine. 2024;11. doi:10.3389/fcvm.2024.1367463
BibTeX
@article{Mergen2024,
author = {Mergen, Victor and Rusek, Stéphane and Civaia, Filippo and Rossi, Philippe and Rajagopal, Rengarajan and Bättig, Eduardo and Manka, Robert and Candreva, Alessandro and Eberhard, Matthias and Alkadhi, Hatem},
title = {Virtual calcium removal in calcified coronary arteries with photon-counting detector CT—first in-vivo experience},
journal = {Frontiers in Cardiovascular Medicine},
year = {2024},
volume = {11},
doi = {10.3389/fcvm.2024.1367463}
}
EUVIMED