EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Case Report: A leadless and endovascular pacemaker teamwork

Sarah Zeriouh, Vasileios Sousonis, Roberto Menè, Serge Boveda, Quentin Voglimacci-Stephanopoli, Stéphane Combes

Frontiers in Cardiovascular Medicine · 09.11.2023 · 10

DOI: 10.3389/fcvm.2023.1287506 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 09.11.2023. Verfasst von Sarah Zeriouh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cardiac Implantable Electronic Device infections increase short- and long-term mortality, along with healthcare costs. Leadless pacemakers (PM) were developed to overcome pocket- and minimize lead-related complications in selected high-risk patients. Recent advancements enable leadless devices to mechanically detect atrial activity, facilitating atrioventricular (AV) synchronous stimulation. Case summary A 90-year-old woman, implanted with a dual-chamber pacemaker eight years ago due to sinus node dysfunction, presented with syncope. A diagnosis of complete AV block, in the setting of ventricular lead dysfunction was made. Due to a high risk of infection, the patient was implanted with a leadless PM capable of maintaining AV synchrony in VDD mode (MICRA™ model MC1AVR1). The transvenous PM was programmed to AAI-R mode to drive the atria, which, in turn, triggered the leadless PM to stimulate the ventricles. At six month follow-up, the AV synchrony rate was 85%.

Conclusion

The combination of classic atrial pacing with leadless ventricular stimulation can be used in high-risk patients to reduce the risk of complications, in the setting of ventricular lead dysfunction. In this manner, AV synchrony can be maintained, improving hemodynamic parameters and quality of life. Low sinus rate variability at rest is essential to achieve a high AV synchrony rate in such cases.

Schlagwörter

Stichwörter der Autor:innen

atrioventricular synchronydevice infectionendovascular pacemakerlead dysfunctionleadless pacemaker

Autor:innen und Institutionen

  • Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France.

Zitieren

APA

Zeriouh, S., Sousonis, V., Menè, R., Boveda, S., Voglimacci-Stephanopoli, Q., & Combes, S. (2023). Case Report: A leadless and endovascular pacemaker teamwork. Frontiers in Cardiovascular Medicine, 10. https://doi.org/10.3389/fcvm.2023.1287506

Vancouver

Zeriouh S, Sousonis V, Menè R, Boveda S, Voglimacci-Stephanopoli Q, Combes S. Case Report: A leadless and endovascular pacemaker teamwork. Frontiers in Cardiovascular Medicine. 2023;10. doi:10.3389/fcvm.2023.1287506

BibTeX
@article{Zeriouh2023,
  author = {Zeriouh, Sarah and Sousonis, Vasileios and Menè, Roberto and Boveda, Serge and Voglimacci-Stephanopoli, Quentin and Combes, Stéphane},
  title = {Case Report: A leadless and endovascular pacemaker teamwork},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2023},
  volume = {10},
  doi = {10.3389/fcvm.2023.1287506}
}
Kostenlos starten →