Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 22.09.2023. Verfasst von Petroula Nana und 7 weiteren Autor:innen. Beteiligte Einrichtung: German Aortic Center, Department of Vascular Medicine, University Heart and Vascular Center UKE Hamburg, Hamburg, Germany. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Endovascular repair using off-the-shelf endografts is a viable solution in patients with ruptured or symptomatic complex aortic aneurysms. This analysis aimed to present the peri-operative and follow-up outcomes in urgent and emergent cases managed with the t-Branch multibranched thoracoabdominal endograft.

Methods

Prospectively collected data from all consecutive urgent and emergent cases managed in two aortic centers between January 1st, 2014, to November 30th, 2022, using the t-Branch device (Cook Medical Inc., Bjaeverskov, Denmark) were analyzed. Patients presenting with ruptured aortic complex aneurysms were characterized as emergent and patients with aneurysms >90 mm of diameter, or symptomatic aneurysms were characterized as urgent. Technical success, 30-day mortality, major adverse events (MAE) and spinal cord ischemia (SCI) rates were assessed.

Results

225 patients (36.5% females, 72.5 ± 2.8 years) were included; 73.0% were urgent. The mean aneurysm diameter was 109 ± 3.9 mm and 44.4% were type I–III TAAAs. Females ( p = .03), para-renal aneurysms ( p = .02) and ASA score IV ( p < .001) were more common in emergent cases. Technical success was 97.8%. Thirty-day mortality and MAE rates were 17.8% and 30.6%, respectively. SCI rate was 14.7%, (4.8% paraplegia rate) with 22.2% of patients receiving prophylactic cerebrospinal drainage. Thirty-day mortality (13.3% vs. 26.7%, p = .04) and MAE (26.0% vs. 43.0%, p = .02) were more common among emergent cases while technical success (97.6% vs. 98.3%, p = .9), and SCI (13.3% vs. 18.3%, p = .4) were similar. Survival at 12-months was 83.5% (SE 5.9%) for the urgent and 77.1% (SE 8.2%) for the emergent group (log rank, p = 0.96).

Conclusion

T-Branch represents an effective and safe solution for the management of urgent and emergent cases with complex aortic aneurysms, with high technical success, promising early mortality and SCI rates.

Schlagwörter

Stichwörter der Autor:innen

branched devicescomplex endovascular repairoff-theshelfrupturedsymptomaticurgent

Autor:innen und Institutionen

  • German Aortic Center, Department of Vascular Medicine, University Heart and Vascular Center UKE Hamburg, Hamburg, Germany.
  • Department of General, Vascular and Transplant Surgery, Medical University of Warsaw, Warsaw, Poland.

Zitieren

APA

Nana, P., Spanos, K., Jakimowicz, T., Torrealba, J. I., Jama, K., Panuccio, G., Rohlffs, F., & Kölbel, T. (2023). Urgent and emergent repair of complex aortic aneurysms using an off-the-shelf branched device. Frontiers in Cardiovascular Medicine, 10. https://doi.org/10.3389/fcvm.2023.1277459

Vancouver

Nana P, Spanos K, Jakimowicz T, Torrealba JI, Jama K, Panuccio G, et al. Urgent and emergent repair of complex aortic aneurysms using an off-the-shelf branched device. Frontiers in Cardiovascular Medicine. 2023;10. doi:10.3389/fcvm.2023.1277459

BibTeX
@article{Nana2023,
  author = {Nana, Petroula and Spanos, Konstantinos and Jakimowicz, Tomasz and Torrealba, Jose I and Jama, Katarzyna and Panuccio, Giuseppe and Rohlffs, Fiona and Kölbel, Tilo},
  title = {Urgent and emergent repair of complex aortic aneurysms using an off-the-shelf branched device},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2023},
  volume = {10},
  doi = {10.3389/fcvm.2023.1277459}
}
Kostenlos starten →