Outcomes of manually modified microvascular plugs to pulmonary flow restrictors in various congenital heart lesions
Frontiers in Cardiovascular Medicine · 10.07.2023 · 10
DOI: 10.3389/fcvm.2023.1150579 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 10.07.2023. Verfasst von Raymond N Haddad und 6 weiteren Autor:innen. Beteiligte Einrichtung: M3C-Necker, Hôpital Universitaire Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The development of microvascular plugs (MVPs) has enabled novel transcatheter deliverable endoluminal pulmonary flow restrictors (PFRs) with the potential to treat newborns and infants with life-threatening congenital heart diseases (CHDs) in a minimally invasive manner. We present our experience to evaluate the efficacy of this concept in controlling pulmonary blood flow in various CHDs.
Methods
Retrospective clinical data review of patients with CHD and pulmonary over-circulation who received bilateral PFRs percutaneously.
Results
Twenty-eight PFRs (7 MVP-5Q, 12 MVP-7Q, and 9 MVP-9Q) were finally implanted in 14 patients with a median age of 1.6 months (IQR, 0.9–2.3) and a median weight of 3.1 Kg (IQR, 2.7–3.6). Nine patients had large intra-cardiac left-to-right shunts (including 3 with fatal trisomy and palliative programs), 2 had borderline left ventricles, 2 had Taussig-Bing anomaly, and one had a hypoplastic left heart. Four patients had concomitant ductal stenting. Two MVP-5Qs were snare-removed and upsized to MVP-7Q. Patients experienced a significant drop in oxygen saturation and Qp/Qs. All patients were discharged from the ICU after a median of 3.5 days (IQR, 2–5.8) postoperative. Five patients had routine inter-stage catheterization and no device embolization or pulmonary branch distortion was seen. Fourteen (50%) PFRs were surgically explanted uneventfully on a median of 4.3 months (IQR, 1.2–6) post-implantation during biventricular repair in 6 patients and stage-2 palliation in one patient. The latter died 1 month post-operative from severe sepsis. Four patients are scheduled for surgical PFR removal and biventricular repair. Two patients with trisomy 18 died at 1 and 6.8 months post-procedure from non-cardiac causes. One patient with trisomy 13 is alive at 2.7 months post-procedure.
Conclusion
It is feasible to bespoke MVPs and implant them as effective PFRs in various CHDs. This approach enables staged left ventricular recruitment, comprehensive stage-2 or biventricular repair with lower risk by postponing surgeries to later infancy. Device explantation is uneventful, and the outcomes afterward are promising.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- M3C-Necker, Hôpital Universitaire Necker-Enfants Malades, Assistance Publique-Hôpitaux de Paris (AP-HP), Paris, France.
- Department of Congenital Cardiology, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.
- Department of Pediatric Cardiology, Heart Centre of Excellence, Al Jalila Children's Speciality Hospital, Dubai, United Arab Emirates.
- Department of Congenital Cardiac Surgery, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.
- Department of Pediatric Cardiac Surgery, Heart Centre of Excellence, Al Jalila Children's Speciality Hospital, Dubai, United Arab Emirates.
Zitieren
APA
Haddad, R. N., Bentham, J., Adel Hassan, A., Al Soufi, M., Jaber, O., El Rassi, I., & Kasem, M. (2023). Outcomes of manually modified microvascular plugs to pulmonary flow restrictors in various congenital heart lesions. Frontiers in Cardiovascular Medicine, 10. https://doi.org/10.3389/fcvm.2023.1150579
Vancouver
Haddad RN, Bentham J, Adel Hassan A, Al Soufi M, Jaber O, El Rassi I, et al. Outcomes of manually modified microvascular plugs to pulmonary flow restrictors in various congenital heart lesions. Frontiers in Cardiovascular Medicine. 2023;10. doi:10.3389/fcvm.2023.1150579
BibTeX
@article{Haddad2023,
author = {Haddad, Raymond N and Bentham, Jamie and Adel Hassan, Ahmed and Al Soufi, Mahmoud and Jaber, Osama and El Rassi, Issam and Kasem, Mohamed},
title = {Outcomes of manually modified microvascular plugs to pulmonary flow restrictors in various congenital heart lesions},
journal = {Frontiers in Cardiovascular Medicine},
year = {2023},
volume = {10},
doi = {10.3389/fcvm.2023.1150579}
}
EUVIMED