Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 08.03.2023. Verfasst von Xiu Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Medicine Center, West China Hospital, Sichuan University, Chengdu, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Herzinsuffizienz
Abstract (Originalsprache)
Aim
This study innovatively proposed the 1-min sit-to-stand test (1-min STST) as an assessment tool for functional capacity in acute decompensated heart failure (ADHF), in which its feasibility and safety were investigated.
Methods
This was a prospective, single-center cohort study. The 1-min STST was performed after the first 48 h of admission when vital signs and Borg score were collected. Lung ultrasound was used to measure pulmonary edema by B-lines before and after the test.
Results
Seventy-five patients were enrolled in the study, of whom 40% were in functional class IV on admission. The mean age was 58.3 ± 15.7 years and 40% of the patients were male. 95% patients accomplished the test and the average number of repetitions was 18 ± 7. No adverse event was recorded during or after the 1-min STST. Blood pressure, heart rate, and degree of dyspnea were increased after the test (all p < 0.001), while oxygen saturation was slightly decreased (97.0 ± 1.6 vs. 96.3 ± 2.0%, p = 0.003). The degree of pulmonary edema (χ 2 = 8.300, p = 0.081) was not significantly changed, while there was a reduction in the absolute number of B-lines [9 (3, 16) vs. 7 (3, 13), p = 0.008].
Conclusion
The application of the 1-min STST in early stage of ADHF appeared to be safe and feasible, which induce neither adverse event nor pulmonary edema. It may serve as a new tool of functional capacity assessment, as well as a reference of exercise rehabilitation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Rehabilitation Medicine Center, West China Hospital, Sichuan University, Chengdu, China.
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China.
Zitieren
APA
Zhang, X., Kang, Y., Luo, Z., Chen, Q., Yang, M., Zeng, J., Yu, P., & Zhang, Q. (2023). Feasibility and safety of 1-min sit-to-stand test in acute decompensated heart failure confirmed by lung ultrasound. Frontiers in Cardiovascular Medicine, 10. https://doi.org/10.3389/fcvm.2023.1103247
Vancouver
Zhang X, Kang Y, Luo Z, Chen Q, Yang M, Zeng J, et al. Feasibility and safety of 1-min sit-to-stand test in acute decompensated heart failure confirmed by lung ultrasound. Frontiers in Cardiovascular Medicine. 2023;10. doi:10.3389/fcvm.2023.1103247
BibTeX
@article{Zhang2023,
author = {Zhang, Xiu and Kang, Yu and Luo, Zeruxin and Chen, Qiaowei and Yang, Mengxuan and Zeng, Jijuan and Yu, Pengming and Zhang, Qing},
title = {Feasibility and safety of 1-min sit-to-stand test in acute decompensated heart failure confirmed by lung ultrasound},
journal = {Frontiers in Cardiovascular Medicine},
year = {2023},
volume = {10},
doi = {10.3389/fcvm.2023.1103247}
}
EUVIMED