EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-pass filter settings and the role and mechanism of discrete ventricular electrograms in left bundle branch pacing

Jiabo Shen, Longfu Jiang, Hao Wu, Hengdong Li, Lu Zhang, Jinyan Zhong, Shanshan Zhuo, Lifang Pan

Frontiers in Cardiovascular Medicine · 11.01.2023 · 9

DOI: 10.3389/fcvm.2022.1059172 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cardiovascular Medicine, online erschienen am 11.01.2023. Verfasst von Jiabo Shen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Hwa Mei Hospital, University of Chinese Academy of Sciences, Ningbo, Zhejiang, China. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The characteristics of discrete intracardiac electrogram (EGM) in selective left bundle branch (SLBB) pacing (SLBBP) have not been described in detail previously. This study aimed to examine the effect of different high-pass filter (HPF) settings on discrete local ventricular components in an intracardiac EGM and to analyze its possible mechanisms.

Methods

This study included 144 patients with indications of permanent cardiac pacing. EGMs were collected at four different HPF settings (30, 60, 100, and 200 Hz) with a low-pass filter at 500 Hz, and their possible mechanisms were analyzed.

Results

LBBP was successfully achieved in 91.0% (131/144) of patients. SLBBP was achieved in 123 patients. The occurrence rates of discrete local ventricular EGM were 16.7, 33.3, 72.9, and 85.4% for HPF settings of 30, 60, 100, and 200 Hz, respectively. The analysis of discrete EGM detection showed significant differences between the different HPF settings. By using the discrete local ventricular component and isoelectric interval as the SLBB capture golden standard, the results of EGMs revealed that the 30 Hz HPF has a sensitivity of 19% and specificity of 100%. The 60 Hz HPF had a sensitivity of 39% and a specificity of 100%. The 100 Hz HPF had a sensitivity of 85% and a specificity of 100%. The 200 Hz HPF had a sensitivity of 100% and specificity of 100%.

Conclusion

An optimal HPF setting of 200 Hz is recommended for discrete local ventricular EGM detection. A discrete local ventricular EGM should exhibit an isoelectric interval. A steep deflection and high-frequency ventricular EGM morphology nearly identify an intrinsic EGM morphology.

Schlagwörter

Stichwörter der Autor:innen

conduction system pacingdiscrete electrogramhigh-pass filter settingsisoelectric intervalleft bundle branch pacing (LBBP)

Autor:innen und Institutionen

  • Department of Cardiology, Hwa Mei Hospital, University of Chinese Academy of Sciences, Ningbo, Zhejiang, China.
  • Department of Global Health, Ningbo Institute of Life and Health Industry, University of Chinese Academy of Sciences, Ningbo, Zhejiang, China.

Zitieren

APA

Shen, J., Jiang, L., Wu, H., Li, H., Zhang, L., Zhong, J., Zhuo, S., & Pan, L. (2023). High-pass filter settings and the role and mechanism of discrete ventricular electrograms in left bundle branch pacing. Frontiers in Cardiovascular Medicine, 9. https://doi.org/10.3389/fcvm.2022.1059172

Vancouver

Shen J, Jiang L, Wu H, Li H, Zhang L, Zhong J, et al. High-pass filter settings and the role and mechanism of discrete ventricular electrograms in left bundle branch pacing. Frontiers in Cardiovascular Medicine. 2023;9. doi:10.3389/fcvm.2022.1059172

BibTeX
@article{Shen2023,
  author = {Shen, Jiabo and Jiang, Longfu and Wu, Hao and Li, Hengdong and Zhang, Lu and Zhong, Jinyan and Zhuo, Shanshan and Pan, Lifang},
  title = {High-pass filter settings and the role and mechanism of discrete ventricular electrograms in left bundle branch pacing},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2023},
  volume = {9},
  doi = {10.3389/fcvm.2022.1059172}
}
Kostenlos starten →