Semantic de-identification of burned-in PHI in DICOM medical images: a deep learning–NLP pipeline validated on clinical and phantom TMM datasets
Frontiers in Computer Science · 31.07.2026 · 8
DOI: 10.3389/fcomp.2026.1838941 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Computer Science, online erschienen am 31.07.2026. Verfasst von Remya Sethulekshmi und 4 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
The growing adoption of AI-based healthcare research has increased the need for properly anonymized medical imaging datasets. PHI within DICOM files - particularly burned-in pixel-level text - poses significant privacy and regulatory risks. Existing methods either focus solely on metadata or remove all detected text indiscriminately, sacrificing clinically relevant annotations.
Methods
This paper proposes a semantic de-identification pipeline integrating YOLOv11n-based text detection, domain-optimized EasyOCR, and a hybrid natural language processing (NLP) classification module combining regular expressions, keyword matching, and named entity recognition. A dual-path architecture processes metadata and pixel-level PHI in parallel, enabling complete DICOM sanitization while preserving non-PHI clinical annotations. The system was evaluated on 1,042 multi-modality DICOM images (CT, MRI, X-ray, ultrasound). As a secondary evaluation, the pipeline was also applied to two tissue-mimicking material (TMM) phantom datasets from TCIA - the RIDER Phantom MRI and Phantom FDA CT (RIDER = Reference Image Database to Evaluate Therapy Response; FDA = Food and Drug Administration) - which served as surrogates for controlled evaluation of metadata and burned-in identifier removal.
Results
The system achieves an F1-score of 95.4%, 96.1% recall, a structural similarity index measure (SSIM) of 0.969, a peak signal-to-noise ratio (PSNR) of 28.9 dB, and processes each image in 2.8 s. It achieves SSIM of 0.986 and PSNR of 49.0 dB on RIDER Phantom MRI, and SSIM of 0.974 and PSNR of 31.5 dB on Phantom FDA CT.
Discussion
These results confirm that the pipeline preserves quantitative pixel fidelity when applied to institutional and device identifiers embedded in phantom acquisitions, supporting blinding for domain-generalization studies across institutions. The modular design supports institutional customisation, making it suitable for clinical research workflows and privacy-compliant phantom imaging pipelines.
Zitieren
APA
Sethulekshmi, R., Pillai, M. J., Ahammed, N., Ramasubbareddy, S., & Cho, Y. Y. (2026). Semantic de-identification of burned-in PHI in DICOM medical images: a deep learning–NLP pipeline validated on clinical and phantom TMM datasets. Frontiers in Computer Science, 8. https://doi.org/10.3389/fcomp.2026.1838941
Vancouver
Sethulekshmi R, Pillai MJ, Ahammed N, Ramasubbareddy S, Cho YY. Semantic de-identification of burned-in PHI in DICOM medical images: a deep learning–NLP pipeline validated on clinical and phantom TMM datasets. Frontiers in Computer Science. 2026;8. doi:10.3389/fcomp.2026.1838941
BibTeX
@article{Sethulekshmi2026,
author = {Sethulekshmi, Remya and Pillai, Manu J. and Ahammed, Nihal and Ramasubbareddy, Somula and Cho, Yong Yun},
title = {Semantic de-identification of burned-in PHI in DICOM medical images: a deep learning–NLP pipeline validated on clinical and phantom TMM datasets},
journal = {Frontiers in Computer Science},
year = {2026},
volume = {8},
doi = {10.3389/fcomp.2026.1838941}
}
EUVIMED