EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

External quality assurance of molecular serotype detection of dengue virus RNA among virus research and diagnostic laboratories in India

Gopinath Ramalingam, Selvi Krishnan, Labanya Mukhopadhyay, Nivedita Gupta, Madhumitha Patchaiyappan, Krishnapriya Subramani, Harmanmeet Kaur, Sucila Thangam Ganesan

Frontiers in Cellular and Infection Microbiology · 2026

DOI: 10.3389/fcimb.2026.1919409 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cellular and Infection Microbiology, 2026. Verfasst von Gopinath Ramalingam und 7 weiteren Autor:innen. Beteiligte Einrichtung: Virus Research and Diagnostic Laboratory, Department of Microbiology, Government Theni Medical College, Theni, India. Hauptthemen laut MEDLINE: Dengue Virus, RNA, Viral, Dengue, Serotyping. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

External Quality Assessment Schemes (EQAS) are essential for ensuring the accuracy, reliability, and comparability of molecular diagnostic testing across laboratory networks. To strengthen dengue molecular surveillance and laboratory quality systems in India, a Pan-Dengue Molecular Serotyping EQAS was developed and implemented among Virus Research and Diagnostic Laboratories (VRDLs) in India.

Methods

A nationwide EQAS was conducted in three rounds between December 2024 and February 2026. Proficiency testing panels consisting of five coded lyophilized serum samples (500 µL each) containing dengue-positive and dengue-negative specimens were prepared, characterized, validated, and distributed to participating laboratories. Homogeneity and stability assessments were performed prior to distribution. Participating laboratories tested the panels using their routine molecular diagnostic workflows and reported dengue detection and serotype identification results through the National Institute of Epidemiology (NIE) PT Panel Portal. Laboratory performance was evaluated based on concordance with assigned reference results.

Results

A total of 34, 40, and 56 laboratories enrolled in Round 1, Round 1 Phase-II, and Round 2, respectively. The corresponding response rates were 91.2%, 95.0%, and 94.6%. Complete concordance was achieved by all reporting laboratories in Round 1 (31/31) and Round 1 Phase-II (38/38). In Round 2, 50/53 laboratories (94.3%) achieved 100% concordance, while two and one laboratory achieved 80% and 60% concordance, respectively. The overall pass rate across all rounds was 97.5%.

Conclusion

The Pan-Dengue Molecular Serotyping EQAS highlighted a high level of proficiency among participating laboratories and effectively strengthened molecular diagnostic quality assurance within the national laboratory network. Regular implementation of such programmes will support reliable dengue surveillance, continuous quality improvement, and enhanced preparedness for dengue outbreaks in India.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dengue VirusRNA, ViralDengueSerotypingLaboratory Proficiency TestingMolecular Diagnostic TechniquesQuality Assurance, Health CareIndiaHumansSerogroupReproducibility of ResultsLaboratoriesQuality Control

Stichwörter der Autor:innen

VRDLdengue virusexternal quality assessment schememolecular serotypingproficiency testingreal-time RT-PCR

Substanzen

RNA, Viral

Autor:innen und Institutionen

  • Virus Research and Diagnostic Laboratory, Department of Microbiology, Government Theni Medical College, Theni, India.
  • Indian Council of Medical Research, V. Ramalingaswami Bhawan, Ansari Nagar, New Delhi, India.
  • Scientist G & Head, Communicable Diseases, Indian Council of Medical Research, V. Ramalingaswami Bhawan, New Delhi, India.

Zitieren

APA

Ramalingam, G., Krishnan, S., Mukhopadhyay, L., Gupta, N., Patchaiyappan, M., Subramani, K., Kaur, H., & Ganesan, S. T. (2026). External quality assurance of molecular serotype detection of dengue virus RNA among virus research and diagnostic laboratories in India. Frontiers in Cellular and Infection Microbiology. https://doi.org/10.3389/fcimb.2026.1919409

Vancouver

Ramalingam G, Krishnan S, Mukhopadhyay L, Gupta N, Patchaiyappan M, Subramani K, et al. External quality assurance of molecular serotype detection of dengue virus RNA among virus research and diagnostic laboratories in India. Frontiers in Cellular and Infection Microbiology. 2026. doi:10.3389/fcimb.2026.1919409

BibTeX
@article{Ramalingam2026,
  author = {Ramalingam, Gopinath and Krishnan, Selvi and Mukhopadhyay, Labanya and Gupta, Nivedita and Patchaiyappan, Madhumitha and Subramani, Krishnapriya and Kaur, Harmanmeet and Ganesan, Sucila Thangam},
  title = {External quality assurance of molecular serotype detection of dengue virus RNA among virus research and diagnostic laboratories in India},
  journal = {Frontiers in Cellular and Infection Microbiology},
  year = {2026},
  doi = {10.3389/fcimb.2026.1919409}
}
Kostenlos starten →