Similar intraoperative microbiomes in de novo and replacement cardiac implantable electronic device pockets support transient contamination over stable colonisation
Frontiers in Cellular and Infection Microbiology · 06.07.2026 · 16
DOI: 10.3389/fcimb.2026.1843081 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Cellular and Infection Microbiology, online erschienen am 06.07.2026. Verfasst von Zhe Xu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Fujian Medical University Union Hospital, Fuzhou, China. Hauptthemen laut MEDLINE: Bacteria, Pacemaker, Artificial, Microbiota, Prosthesis-Related Infections. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The source of bacteria detected in cardiac implantable electronic device (CIED) pockets—whether true colonisation or intraoperative contamination—has significant implications for infection prevention strategies.
Aim
To compare intraoperative microbial dynamics during de novo pacemaker implantation versus generator replacement using 16S rRNA gene sequencing.
Methods
In this prospective study, samples were collected from 18 asymptomatic patients (11 new implants, seven replacements) at three timepoints: skin before incision (T1), pocket after creation (T2), and pocket before closure (T3). Microbiome analysis was performed via 16S rRNA gene sequencing of the V3-V4 region. α-diversity (Simpson index) and β-diversity (Bray–Curtis dissimilarity) were analysed.
Findings
Microbial community composition and relative abundance were similar between groups at all timepoints. Predominant genera included A chromobacter, Pedobacter, Pseudomonas, Acinetobacter, Blastococcus, and Paracoccus . No significant differences in α- or β-diversity were found between new and replacement groups at T2 and T3. The only significant difference was a higher α-diversity at T1 (skin) in the new implantation group ( P = 0.037), likely reflecting age-related skin flora differences. No patient developed a clinical infection during follow-up (mean 9.4 ± 1.8 months).
Conclusion
The absence of distinct microbial signatures in replacement pockets and the prevalence of environmental bacteria strongly suggest that detected microorganisms originate from intraoperative contamination. This underscores the paramount importance of rigorous aseptic technique over surveillance for colonization in preventing CIED infections.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiology, Fujian Medical University Union Hospital, Fuzhou, China.
- Fujian Cardiovascular Medical Centre, Fuzhou, China.
- Fujian Institute of Coronary Heart Disease, Fuzhou, China.
- Fujian Cardiovascular Research Centre, Fuzhou, China.
- Fujian Medical University Heart Centre, Fuzhou, China.
Zitieren
APA
Xu, Z., Chen, X., Gong, K., Zhang, F., & Lin, Y. (2026). Similar intraoperative microbiomes in de novo and replacement cardiac implantable electronic device pockets support transient contamination over stable colonisation. Frontiers in Cellular and Infection Microbiology, 16. https://doi.org/10.3389/fcimb.2026.1843081
Vancouver
Xu Z, Chen X, Gong K, Zhang F, Lin Y. Similar intraoperative microbiomes in de novo and replacement cardiac implantable electronic device pockets support transient contamination over stable colonisation. Frontiers in Cellular and Infection Microbiology. 2026;16. doi:10.3389/fcimb.2026.1843081
BibTeX
@article{Xu2026,
author = {Xu, Zhe and Chen, Xuehai and Gong, Kezeng and Zhang, Feilong and Lin, Yunling},
title = {Similar intraoperative microbiomes in de novo and replacement cardiac implantable electronic device pockets support transient contamination over stable colonisation},
journal = {Frontiers in Cellular and Infection Microbiology},
year = {2026},
volume = {16},
doi = {10.3389/fcimb.2026.1843081}
}
EUVIMED