EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Total laboratory automation-based monitoring processes: setup and validation of an integrated internal quality control panel

Adrien Fischer, Abdessalam Cherkaoui, Didier Schorderet, Julie Wagner, Jacques Schrenzel

Frontiers in Cellular and Infection Microbiology · 2026

DOI: 10.3389/fcimb.2026.1771552 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cellular and Infection Microbiology, 2026. Verfasst von Adrien Fischer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Bacteriology Laboratory, Department of Diagnostics, Geneva University Hospitals, Geneva, Switzerland. Hauptthemen laut MEDLINE: Automation, Laboratory, Quality Control, Bacteriological Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Total laboratory automation (TLA) is now widely implemented in diagnostic microbiology laboratories. However, a coherent and standardized quality surveillance procedure for all the automated culture-based processes is currently lacking.

Objectives

We set up and implemented an internal quality control (IQC) panel to assess the automated culture-based processes and workflows.

Methods

A subset of reference strains was applied to monitor liquid and solid culture media used in all culture-based processes on the TLA. This integrated IQC panel monitors staining, automated plate streaking, incubation and digital imaging, artificial intelligence (AI)-assisted plate reading, identification by MALDI-ToF-MS, fully automated antimicrobial disc diffusion susceptibility testing, minimum inhibitory concentration (MIC) determination by broth microdilution and E-test strips, and finally, detection of the defined antimicrobial resistance genes by molecular assays.

Results

During 6 months of implementation of this new routine IQC approach, no errors were detected regarding all the culture-based and antimicrobial susceptibility testing (AST) processes, including antimicrobial resistance gene detection, with the exception of one major error related to a MIC misreading for imipenem.

Conclusions

This IQC approach ensures the traceability and control of the analytical phase of an automated laboratory. Annual costs for these integrated IQC panels amounted to CHF 17,886.-, of which 53% were related to personal time costs. The latter could be improved by further software development for sample prescription, data collection, and reporting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Automation, LaboratoryQuality ControlBacteriological TechniquesMicrobial Sensitivity TestsHumansCulture MediaBacteriaAnti-Bacterial Agents

Stichwörter der Autor:innen

diagnostic laboratoryinternal quality controlmicrobiologyquality costsreference strainstotal laboratory automation (TLA)

Substanzen

Culture MediaAnti-Bacterial Agents

Autor:innen und Institutionen

  • Bacteriology Laboratory, Department of Diagnostics, Geneva University Hospitals, Geneva, Switzerland.

Zitieren

APA

Fischer, A., Cherkaoui, A., Schorderet, D., Wagner, J., & Schrenzel, J. (2026). Total laboratory automation-based monitoring processes: setup and validation of an integrated internal quality control panel. Frontiers in Cellular and Infection Microbiology. https://doi.org/10.3389/fcimb.2026.1771552

Vancouver

Fischer A, Cherkaoui A, Schorderet D, Wagner J, Schrenzel J. Total laboratory automation-based monitoring processes: setup and validation of an integrated internal quality control panel. Frontiers in Cellular and Infection Microbiology. 2026. doi:10.3389/fcimb.2026.1771552

BibTeX
@article{Fischer2026,
  author = {Fischer, Adrien and Cherkaoui, Abdessalam and Schorderet, Didier and Wagner, Julie and Schrenzel, Jacques},
  title = {Total laboratory automation-based monitoring processes: setup and validation of an integrated internal quality control panel},
  journal = {Frontiers in Cellular and Infection Microbiology},
  year = {2026},
  doi = {10.3389/fcimb.2026.1771552}
}
Kostenlos starten →