EBUS-TBNA needle rinse fluid: a superior specimen for the molecular diagnosis of intrathoracic lymph node tuberculosis
Frontiers in Cellular and Infection Microbiology · 2026
DOI: 10.3389/fcimb.2025.1734956 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Cellular and Infection Microbiology, 2026. Verfasst von Yayan Niu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Tuberculosis, The Fifth People's Hospital of Suzhou/The Affiliated Infectious Diseases Hospital, Suzhou Medical College of Soochow Univ…. Hauptthemen laut MEDLINE: Tuberculosis, Lymph Node, Molecular Diagnostic Techniques, Endoscopic Ultrasound-Guided Fine Needle Aspiration. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Program of Suzhou, Suzhou Gusu Medical Youth Talent, Natural Science Foundation of Jiangsu Province.
Abstract (Originalsprache)
Objectives
To evaluate EBUS-TBNA needle rinse fluid versus biopsy tissue for molecular diagnosis of intrathoracic lymph node tuberculosis (TB).
Methods
Retrospective analysis of 63 patients with intrathoracic lymph node TB undergoing EBUS-TBNA (2018–2024). Rinse fluid and biopsy tissue were tested via TB-DNA (n=32) and Xpert MTB/RIF (n=31); positivity rates compared.
Results
The study cohort had a median age of 31 years (interquartile range: 25–50.1 years), with 57.1% (36/63) being male. The most frequently sampled lymph node stations were subcarinal (station 7, 82.5%) and right lower mediastinal (station 4R, 66.7%). Clinically, 82.5% (52/63) of patients had concomitant pulmonary TB, while 17.5% (11/63) presented with isolated intrathoracic lymph node TB. For TB-DNA detection, the positivity rate of rinse fluid (71.9%, 23/32) was significantly higher than that of biopsy tissue (46.9%, 15/32; χ²=4.146, P = 0.042). Similarly, the Xpert MTB/RIF assay showed a higher positivity rate in rinse fluid (77.4%, 24/31) compared to tissue (41.9%, 13/31; χ²=8.11, P = 0.004).
Conclusions
EBUS-TBNA rinse fluid demonstrates higher sensitivity than biopsy tissue for intrathoracic lymph node TB via TB-DNA/Xpert MTB/RIF. Routine rinse fluid testing improves diagnostic yield.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Tuberculosis, The Fifth People's Hospital of Suzhou/The Affiliated Infectious Diseases Hospital, Suzhou Medical College of Soochow University, Suzhou, China.
- Department of Traditional Chinese Medicine, The Fifth People's Hospital of Suzhou/The Affiliated Infectious Diseases Hospital, Suzhou Medical College of Soochow University, Suzhou, China.
- Department of Clinical Laboratory, The Fifth People's Hospital of Suzhou/The Affiliated Infectious Diseases Hospital, Suzhou Medical College of Soochow University, Suzhou, China.
Förderung
- Science and Technology Program of Suzhou
- Suzhou Gusu Medical Youth Talent
- Natural Science Foundation of Jiangsu Province
Zitieren
APA
Niu, Y., Li, X., Yan, J. Y., Song, H., Yao, L., Zhang, L., Wu, M., Tang, P., Xu, J., & Feng, Y. (2026). EBUS-TBNA needle rinse fluid: a superior specimen for the molecular diagnosis of intrathoracic lymph node tuberculosis. Frontiers in Cellular and Infection Microbiology. https://doi.org/10.3389/fcimb.2025.1734956
Vancouver
Niu Y, Li X, Yan JY, Song H, Yao L, Zhang L, et al. EBUS-TBNA needle rinse fluid: a superior specimen for the molecular diagnosis of intrathoracic lymph node tuberculosis. Frontiers in Cellular and Infection Microbiology. 2026. doi:10.3389/fcimb.2025.1734956
BibTeX
@article{Niu2026,
author = {Niu, Yayan and Li, Xiaohong and Yan, Jin Yu and Song, Huafeng and Yao, Lin and Zhang, Lijuan and Wu, Meiying and Tang, Peijun and Xu, Junchi and Feng, Yanjun},
title = {EBUS-TBNA needle rinse fluid: a superior specimen for the molecular diagnosis of intrathoracic lymph node tuberculosis},
journal = {Frontiers in Cellular and Infection Microbiology},
year = {2026},
doi = {10.3389/fcimb.2025.1734956}
}
EUVIMED