EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Visual and rapid identification of Chlamydia trachomatis and Neisseria gonorrhoeae using multiplex loop-mediated isothermal amplification and a gold nanoparticle-based lateral flow biosensor

Xu Chen, Qingxue Zhou, Wei Yuan, Yuanfang Shi, Shilei Dong, Xinhua Luo

Frontiers in Cellular and Infection Microbiology · 2023

DOI: 10.3389/fcimb.2023.1067554 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cellular and Infection Microbiology, 2023. Verfasst von Xu Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: The Second Clinical College, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, China. Hauptthemen laut MEDLINE: Chlamydia Infections, Biosensing Techniques, Metal Nanoparticles. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sexually transmitted chlamydia and gonorrhea infections caused by the bacteria Chlamydia trachomatis and Neisseria gonorrhoeae remain a major public health concern worldwide, particularly in less developed nations. It is crucial to use a point of care (POC) diagnostic method that is quick, specific, sensitive, and user-friendly to treat and control these infections effectively. Here, a novel molecular diagnostic assay, combining multiplex loop-mediated isothermal amplification (mLAMP) with a visual gold nanoparticles-based lateral flow biosensor (AuNPs-LFB) was devised and used for highly specific, sensitive, rapid, visual, and easy identification of C. trachomatis and N. gonorrhoeae . Two unique independent primer pairs were successful designed against the ompA and orf1 genes of C. trachomatis and N. gonorrhoeae , respectively. The optimal mLAMP-AuNPs-LFB reaction conditions were determined to be 67°C for 35 min. The detection procedure, involving crude genomic DNA extraction (~5 min), LAMP amplification (35 min), and visual results interpretation (<2 min), can be completed within 45 min. Our assay has a detection limit of 50 copies per test, and we did not observe any cross-reactivity with any other bacteria in our testing. Hence, our mLAMP-AuNPs-LFB assay can potentially be used for POC testing to detect C. trachomatis and N. gonorrhoeae in clinical settings, particularly in underdeveloped regions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Chlamydia InfectionsBiosensing TechniquesMetal NanoparticlesSensitivity and SpecificityNucleic Acid Amplification TechniquesNeisseria gonorrhoeaeGoldChlamydia trachomatisHumansMolecular Diagnostic Techniques

Stichwörter der Autor:innen

Chlamydia trachomatisNeisseria gonorrhoeaegold nanoparticle-based lateral flow biosensorloop-mediated isothermal amplificationpoint-of-care testing

Substanzen

Gold

Autor:innen und Institutionen

  • The Second Clinical College, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, China.
  • Clinical Medical Laboratory of the Second Affiliated Hospital, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou, China.
  • Clinical Laboratory, Hangzhou Women's Hospital, Hangzhou, Zhejiang, China.
  • Department of Quality Control, Guizhou Provincial Center for Clinical Laboratory, Guiyang, Guizhou, China.
  • Department of Clinical Laboratory, Zhejiang Hospital, Hangzhou, Zhejiang, China.
  • Department of Infectious Disease, Guizhou Provincial People's Hospital, Guiyang, Guizhou, China.

Zitieren

APA

Chen, X., Zhou, Q., Yuan, W., Shi, Y., Dong, S., & Luo, X. (2023). Visual and rapid identification of Chlamydia trachomatis and Neisseria gonorrhoeae using multiplex loop-mediated isothermal amplification and a gold nanoparticle-based lateral flow biosensor. Frontiers in Cellular and Infection Microbiology. https://doi.org/10.3389/fcimb.2023.1067554

Vancouver

Chen X, Zhou Q, Yuan W, Shi Y, Dong S, Luo X. Visual and rapid identification of Chlamydia trachomatis and Neisseria gonorrhoeae using multiplex loop-mediated isothermal amplification and a gold nanoparticle-based lateral flow biosensor. Frontiers in Cellular and Infection Microbiology. 2023. doi:10.3389/fcimb.2023.1067554

BibTeX
@article{Chen2023,
  author = {Chen, Xu and Zhou, Qingxue and Yuan, Wei and Shi, Yuanfang and Dong, Shilei and Luo, Xinhua},
  title = {Visual and rapid identification of Chlamydia trachomatis and Neisseria gonorrhoeae using multiplex loop-mediated isothermal amplification and a gold nanoparticle-based lateral flow biosensor},
  journal = {Frontiers in Cellular and Infection Microbiology},
  year = {2023},
  doi = {10.3389/fcimb.2023.1067554}
}
Kostenlos starten →