EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Highly sensitive electrochemical immunosensor based on methylene blue-reduced graphene oxide nanocomposites as signal probes for IL-6 detection in gingival crevicular fluid samples

Changfeng Zhu, Hongxin Wang, Jiyang Liu

Frontiers in Chemistry · 02.04.2025 · 13

DOI: 10.3389/fchem.2025.1549927 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Chemistry, online erschienen am 02.04.2025. Verfasst von Changfeng Zhu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Stomatology, Beijing Hospital of Integrated Traditional Chinese and Western Medicine, Beijing, China. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As an important inflammatory cytokine, interleukin-6 (IL-6) can mediate the entire pathological process of periodontitis and is closely associated with the degree of inflammation. Therefore, it is critical to develop convenient quantitative methods for monitoring IL-6 quantity in gingival crevicular fluid. In this study, methylene blue (MB)-decorated reduced graphene oxide (rGO) is employed as signal probe to further support the antibody-enabling specific recognition of IL-6. Due to π–π stacking and electrostatic interactions, rGO-MB nanocomposites can be stably obtained. rGO with good conductivity and large surface area characteristics promotes the redox signals of MB on the glassy carbon electrode (GCE). In addition, through the simple in situ self-polymerization of dopamine, the polydopamine (PDA) obtained can be not only directly used as a biological crosslinking agent for covalent immobilization of anti-IL-6 antibody but can also be regarded as a protective layer to enhance the stability of rGO-MB on the GCE surface. Such a designed PDA/rGO-MB/GCE-based immunosensor enables specific binding with IL-6 and produces a decreased electrochemical signal for MB, realizing the selective and sensitive quantitative measurement of IL-6. Consequently, our fabricated PDA/rGO-MB/GCE-based electrochemical immunosensor has an excellent linear relationship with IL-6 ranging from 1 pg/mL to 100 ng/mL, with a limit of detection as low as 0.48 pg/mL. Moreover, our as-prepared sensing strategy shows accurate monitoring of the IL-6 quantity in gingival crevicular fluid samples.

Schlagwörter

Stichwörter der Autor:innen

IL-6electrochemical immunosensormethylene bluepolydopaminereduced graphene oxide

Autor:innen und Institutionen

  • Department of Stomatology, Beijing Hospital of Integrated Traditional Chinese and Western Medicine, Beijing, China.
  • Key Laboratory of Surface & Interface Science of Polymer Materials of Zhejiang Province, Department of Chemistry, School of Chemistry and Chemical Engineering, Zhejiang Sci-Tech University, Hangzhou, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhu, C., Wang, H., & Liu, J. (2025). Highly sensitive electrochemical immunosensor based on methylene blue-reduced graphene oxide nanocomposites as signal probes for IL-6 detection in gingival crevicular fluid samples. Frontiers in Chemistry, 13. https://doi.org/10.3389/fchem.2025.1549927

Vancouver

Zhu C, Wang H, Liu J. Highly sensitive electrochemical immunosensor based on methylene blue-reduced graphene oxide nanocomposites as signal probes for IL-6 detection in gingival crevicular fluid samples. Frontiers in Chemistry. 2025;13. doi:10.3389/fchem.2025.1549927

BibTeX
@article{Zhu2025,
  author = {Zhu, Changfeng and Wang, Hongxin and Liu, Jiyang},
  title = {Highly sensitive electrochemical immunosensor based on methylene blue-reduced graphene oxide nanocomposites as signal probes for IL-6 detection in gingival crevicular fluid samples},
  journal = {Frontiers in Chemistry},
  year = {2025},
  volume = {13},
  doi = {10.3389/fchem.2025.1549927}
}
Kostenlos starten →