EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Refractive error after phacoemulsification combined with intraocular lens implantation in primary angle-closure glaucoma: a multifactorial analysis of biometric parameters and surgical strategies

Yong Liu, Kuanrong Dang, Di Gong, Simin Deng, Yin Deng, Junhong Guo, Xiaoli Shen, Jiantao Wang

Frontiers in Cell and Developmental Biology · 22.08.2025 · 13

DOI: 10.3389/fcell.2025.1654719 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Cell and Developmental Biology, online erschienen am 22.08.2025. Verfasst von Yong Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Jinan University, Guangzhou, Guangdong, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aims to explore the factors influencing refractive error following Phacoemulsification combined with intraocular lens implantation (PE + IOL) in patients with primary angle-closure glaucoma (PACG), providing a theoretical basis for preoperative consultation and IOL power selection in clinical practice.

Methods

A retrospective analysis was conducted on 404 PACG patients from Shenzhen Eye Hospital between 2019 and 2024. Preoperative ocular biometric parameters and combined surgical approaches were evaluated using Spearman correlation, multinomial logistic regression, and receiver operating characteristic (ROC) curve analysis.

Results

Axial length (AL), lens thickness (LT), and white-to-white distance (WTW) were key predictive factors for prediction error and postoperative refractive outcomes. AL > 22.56 mm (AUC = 0.692) and LT > 5.055 mm (AUC = 0.633) increased the risk of myopic shift (MS), while AL < 22.25 mm (AUC = 0.604) and WTW <11.55 mm (OR = 2.209, P = 0.001) were associated with hyperopic shift (HS). The axial length/corneal radius (AL/CR) ratio >2.986 further indicated a higher risk of MS (AUC = 0.639) postoperatively. Among patients who underwent PE + IOL combined with capsular tension ring, the proportion of HS was significantly higher (Z value = +2.95).

Conclusion

The unique anatomical characteristics of PACG patients are key contributors to postoperative refractive instability. Preoperative assessment for PE + IOL surgery should comprehensively evaluate AL, LT, WTW, and AL/CR ratio. When combined with other surgical approaches to control intraocular pressure, IOL power should be adjusted according to these thresholds to ensure postoperative refractive stability.

Schlagwörter

Stichwörter der Autor:innen

cataract surgerypostoperative refractive outcomesprediction errorprimary angle-closure glaucomarefractive error

Autor:innen und Institutionen

  • Jinan University, Guangzhou, Guangdong, China.
  • Shenzhen Eye Hospital, Shenzhen Eye Medical Center, Southern Medical University, Guangzhou, China.
  • The Second Clinical Medical College (Shenzhen People's Hospital) of Jinan University, Shenzhen, China.

Zitieren

APA

Liu, Y., Dang, K., Gong, D., Deng, S., Deng, Y., Guo, J., Shen, X., & Wang, J. (2025). Refractive error after phacoemulsification combined with intraocular lens implantation in primary angle-closure glaucoma: a multifactorial analysis of biometric parameters and surgical strategies. Frontiers in Cell and Developmental Biology, 13. https://doi.org/10.3389/fcell.2025.1654719

Vancouver

Liu Y, Dang K, Gong D, Deng S, Deng Y, Guo J, et al. Refractive error after phacoemulsification combined with intraocular lens implantation in primary angle-closure glaucoma: a multifactorial analysis of biometric parameters and surgical strategies. Frontiers in Cell and Developmental Biology. 2025;13. doi:10.3389/fcell.2025.1654719

BibTeX
@article{Liu2025,
  author = {Liu, Yong and Dang, Kuanrong and Gong, Di and Deng, Simin and Deng, Yin and Guo, Junhong and Shen, Xiaoli and Wang, Jiantao},
  title = {Refractive error after phacoemulsification combined with intraocular lens implantation in primary angle-closure glaucoma: a multifactorial analysis of biometric parameters and surgical strategies},
  journal = {Frontiers in Cell and Developmental Biology},
  year = {2025},
  volume = {13},
  doi = {10.3389/fcell.2025.1654719}
}
Kostenlos starten →