Summer indoor thermal-humidity environment and thermal comfort of older adults in renovated nursing homes: a case study in Changsha, China

Fupeng Zhang, Lei Shi, Ying Zhang, Simian Liu, Meizhen Long, Wenqian Jiang

Frontiers in Built Environment · 04.08.2026 · 12

DOI: 10.3389/fbuil.2026.1895428 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Built Environment, online erschienen am 04.08.2026. Verfasst von Fupeng Zhang und 5 weiteren Autor:innen. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the increasing demand for urban building stock renewal and elderly care facilities, nursing homes renovated from existing buildings have become increasingly common in hot-summer and cold-winter regions. However, whether their indoor thermal-humidity environments can meet the comfort and health needs of older adults remains insufficiently investigated. This study selected three typical renovated nursing homes in Changsha, China, as case buildings. Field measurements, subjective questionnaire surveys, and thermal comfort model analysis were conducted to investigate the summer indoor thermal-humidity environment in bedrooms and the thermal comfort requirements of older adults. The results show that indoor temperatures in the three nursing homes were higher than the comfort range to varying degrees in summer. The relative humidity generally remained within the allowable range of relevant standards, although periodic high-humidity conditions occurred in some rooms. The questionnaire results showed that 34.7% of the respondents perceived the indoor thermal comfort as neutral, while the overall dissatisfaction rate with the indoor physical environment was 12.8%. The thermal comfort model analysis indicated that the measured summer neutral temperature in the nursing homes in Changsha was 27.8 °C, which was 1.5 °C higher than the neutral temperature predicted by the PMV model. The actual 80% acceptable thermal comfort temperature range for older adults was 25.7 °C–29.9 °C, which was higher than the predicted range of 23.5 °C–27.7 °C. The summer thermal expectation temperature was 28.3 °C. These findings suggest that older adults in Changsha have developed a certain degree of thermal adaptation to relatively high summer temperatures, and that the conventional PMV model may underestimate their acceptability of warmer indoor environments. Therefore, summer thermal environment optimization in renovated nursing homes should comprehensively consider the thermal insulation of building envelopes, shading and ventilation, air-conditioning dehumidification, and individual adaptive behaviors of older adults. This study provides a reference for the thermal environment optimization design and operation management of existing buildings converted into nursing homes in hot-summer and cold-winter regions.

Zitieren

APA

Zhang, F., Shi, L., Zhang, Y., Liu, S., Long, M., & Jiang, W. (2026). Summer indoor thermal-humidity environment and thermal comfort of older adults in renovated nursing homes: a case study in Changsha, China. Frontiers in Built Environment, 12. https://doi.org/10.3389/fbuil.2026.1895428

Vancouver

Zhang F, Shi L, Zhang Y, Liu S, Long M, Jiang W. Summer indoor thermal-humidity environment and thermal comfort of older adults in renovated nursing homes: a case study in Changsha, China. Frontiers in Built Environment. 2026;12. doi:10.3389/fbuil.2026.1895428

BibTeX
@article{Zhang2026,
  author = {Zhang, Fupeng and Shi, Lei and Zhang, Ying and Liu, Simian and Long, Meizhen and Jiang, Wenqian},
  title = {Summer indoor thermal-humidity environment and thermal comfort of older adults in renovated nursing homes: a case study in Changsha, China},
  journal = {Frontiers in Built Environment},
  year = {2026},
  volume = {12},
  doi = {10.3389/fbuil.2026.1895428}
}
Kostenlos starten →