Biomaterial-enabled monitoring of gastrointestinal leakage and anastomotic compromise: material mechanisms and postoperative observation
Frontiers in Bioengineering and Biotechnology · 23.11.2026 · 14
DOI: 10.3389/fbioe.2026.2015621 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 23.11.2026. Verfasst von Yuzhou Cai und 2 weiteren Autor:innen. Die Arbeit nennt 234 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Responsive biomaterials can translate postoperative chemistry and physiology into signals of tissue condition, local fluid exposure and loss of containment. This critical review examines how network design, tissue interfaces and readout architecture determine the meaning and duration of those observations. Three overlapping functions organize the synthesis: current-state monitoring, exposure recording and single-use alarms. Transport, binding and reaction govern whether a material follows present conditions or retains earlier exposure; tissue remodeling, protection and reader access determine its functional observation window. In sensing seals, adhesion and barrier structure also redirect the fluid supplying the signal. Within-study comparisons distinguish partitioning from mobility, retained responsiveness from calibration accuracy, and interfacial attachment from bulk mechanics. Gastrointestinal experiments demonstrate physiological recording, delayed interrogation of persistent material changes and accessible fluid sampling, while emerging human evidence remains heterogeneous in surgical setting and acquisition protocol. We derive task-matched design priorities: preserve the temporal meaning of the signal, maintain target and reader access, and evaluate the assembled device under the mechanical and chemical conditions of its intended site. Clinical translation requires a defined confirmatory-care pathway and evidence that usable information improves assessment without delaying indicated treatment.
Zitieren
APA
Cai, Y., Shi, C., & Zeng, Y. (2026). Biomaterial-enabled monitoring of gastrointestinal leakage and anastomotic compromise: material mechanisms and postoperative observation. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.2015621
Vancouver
Cai Y, Shi C, Zeng Y. Biomaterial-enabled monitoring of gastrointestinal leakage and anastomotic compromise: material mechanisms and postoperative observation. Frontiers in Bioengineering and Biotechnology. 2026;14. doi:10.3389/fbioe.2026.2015621
BibTeX
@article{Cai2026,
author = {Cai, Yuzhou and Shi, Chengmin and Zeng, Yujian},
title = {Biomaterial-enabled monitoring of gastrointestinal leakage and anastomotic compromise: material mechanisms and postoperative observation},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2026},
volume = {14},
doi = {10.3389/fbioe.2026.2015621}
}