EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Lower-limb biomechanics during high-load back squats with device-restricted ankle dorsiflexion

Cheng Chen, Junjie Tao, Di Lu, Jiaxin He

Frontiers in Bioengineering and Biotechnology · 16.11.2026 · 14

DOI: 10.3389/fbioe.2026.1979540 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 16.11.2026. Verfasst von Cheng Chen und 3 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ankle dorsiflexion influences lower-limb mechanics during squatting, but its role during high-load resistance exercise remains unclear. This study compared lower-limb sagittal-plane kinematics and kinetics between unrestricted and device-restricted ankle conditions during high-load back squatting and examined whether condition-related responses differed between limbs. Eleven participants completed both conditions in a fixed-order within-subject design. In the device-restricted condition, the restriction device was mechanically set to permit a maximum dorsiflexion angle of 10° at each ankle. Squats were performed using 100% of each participant’s 5RM. Three-dimensional kinematics and ground-reaction forces were collected, and net internal joint moments were calculated using inverse dynamics. Compared with the unrestricted condition, the device-restricted condition showed lower knee flexion, lower peak net internal knee and ankle joint moment magnitudes, lower limb-specific vertical ground reaction force at peak total vertical ground reaction force, lower peak total vertical ground reaction force, and greater trunk inclination. Peak net internal hip joint moment magnitude did not differ between conditions. A significant Condition × Side interaction was observed for peak net internal knee joint moment magnitude, although both limbs showed lower values under the device-restricted condition; this interaction was considered exploratory. Overall, the device-restricted condition was associated with altered squat mechanics during high-load squatting. Because condition order was fixed and footwear/device characteristics differed between conditions, the findings should not be interpreted as isolating a causal effect of ankle dorsiflexion restriction.

Zitieren

APA

Chen, C., Tao, J., Lu, D., & He, J. (2026). Lower-limb biomechanics during high-load back squats with device-restricted ankle dorsiflexion. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.1979540

Vancouver

Chen C, Tao J, Lu D, He J. Lower-limb biomechanics during high-load back squats with device-restricted ankle dorsiflexion. Frontiers in Bioengineering and Biotechnology. 2026;14. doi:10.3389/fbioe.2026.1979540

BibTeX
@article{Chen2026,
  author = {Chen, Cheng and Tao, Junjie and Lu, Di and He, Jiaxin},
  title = {Lower-limb biomechanics during high-load back squats with device-restricted ankle dorsiflexion},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2026},
  volume = {14},
  doi = {10.3389/fbioe.2026.1979540}
}
Kostenlos starten →