Association of passive posterolateral corner rotational compliance with tibial external-rotation excursion during functional movement: a cross-sectional laboratory study
Frontiers in Bioengineering and Biotechnology · 18.11.2026 · 14
DOI: 10.3389/fbioe.2026.1967094 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 18.11.2026. Verfasst von Dapeng Li und 6 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Importance The posterolateral corner (PLC) is the principal passive restraint to tibial external rotation, but whether PLC compliance relates to cutting external-rotation excursion in uninjured knees remains unclear.
Objective
The aim of this study is to estimate the association between passive PLC rotational compliance and tibial external-rotation excursion during 45-degree cutting. Design, setting, and participants A single-center, cross-sectional laboratory study was conducted on 33 uninjured athletes (January–February 2026) who underwent passive laxity testing, ultrasound with shear-wave elastography, and three-dimensional motion capture. Exposure PLC rotational compliance (deg/Nm): tibial external rotation under a 10-N·m torque, relative to 0 N·m, divided by torque; mean of two supine trials at each of 30°, 60°, and 90°. Main outcomes and measures Primary outcomes included tibial external-rotation excursion during cutting (peak minus initial-contact angle; mean of three trials). Secondary outcomes included other tasks, kinetics, and ultrasound measures, including fibular collateral ligament (FCL) strain (load-induced elongation/pre-load length).
Results
Among 33 participants (17 [52%] female; mean [SD] age, 21.4 [2.3] years), compliance decreased from 30° to 90° (−0.34 deg/Nm; 95% CI = −0.37 to −0.30), and external-rotation loading increased FCL strain at 30° by 4.0 percentage points (95% CI, 3.8–4.3). Compliance had high within-session reliability (intraclass correlation coefficient = 0.88–0.93). Greater compliance was associated with greater excursion in unadjusted analysis (β = 3.1 deg per deg/Nm; 95% CI = 0.7–5.6; P = 0.014); after prespecified adjustment, the estimate was attenuated, primarily by sex, was not statistically significant (β = 1.9; 95% CI = −0.6 to 4.4; P = 0.130), and was sensitive to two influential participants. The standardized adjusted compliance coefficient was 0.26 (95% CI = −0.08 to 0.59), compatible with null to large associations. Trial-level estimates were similar for cutting (β = 2.3; 95% CI = −0.2 to 4.8; P = 0.069) and, post hoc , for all tasks pooled (β = 2.4; 95% CI = 0.3–4.6). No secondary association across the three prespecified false-discovery-rate families remained significant after controlling the false discovery rate at 5%. Conclusion and relevance The association between passive PLC compliance and cutting excursion was largely shared with sex; after adjustment, it was neither established nor excluded. In uninjured athletes, when sex is considered, supine passive compliance should not be regarded as interchangeable with dynamic excursion or as a substitute for dynamic assessment.
Zitieren
APA
Li, D., Ding, Y., Xiao, X., Wen, Z., Shen, H., Fan, X., & Xue, Z. (2026). Association of passive posterolateral corner rotational compliance with tibial external-rotation excursion during functional movement: a cross-sectional laboratory study. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.1967094
Vancouver
Li D, Ding Y, Xiao X, Wen Z, Shen H, Fan X, et al. Association of passive posterolateral corner rotational compliance with tibial external-rotation excursion during functional movement: a cross-sectional laboratory study. Frontiers in Bioengineering and Biotechnology. 2026;14. doi:10.3389/fbioe.2026.1967094
BibTeX
@article{Li2026,
author = {Li, Dapeng and Ding, Yuan and Xiao, Xiao and Wen, Zhenxing and Shen, Hui and Fan, Xiao and Xue, Zichao},
title = {Association of passive posterolateral corner rotational compliance with tibial external-rotation excursion during functional movement: a cross-sectional laboratory study},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2026},
volume = {14},
doi = {10.3389/fbioe.2026.1967094}
}
EUVIMED