Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 16.07.2026. Verfasst von Zulong Zhou und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, The Third Affiliated Hospital of Anhui Medical University (The First People's Hospital of Hefei), Anhui Medical University…. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Minimally invasive surgical treatment is increasingly favored for intra-articular displaced calcaneal fractures with a high risk of soft tissue complications. The calcaneus is the largest tarsal bone in the foot and plays a critical role in weight-bearing and gait mechanics; displaced fractures often result in significant functional impairment. Sanders Type II fractures, characterized by a single major fracture line that divides the posterior articular surface into two major bone fragments, are one of the most common subtypes and present a therapeutic challenge in balancing mechanical stability with soft tissue preservation.
Methods
A finite element model of Sanders Type II calcaneal fractures was established to compare five fixation methods under physiological tendon loading: (1) a periosteal locking plate, (2) four hollow screws, (3) four K-wires placed along the screw trajectory, (4) two intra-articular K-wires combined with two standard K-wires, and (5) six K-wires placed at dispersed locations. Outcome measures included maximum fragment displacement, implant-induced bone stress, and implant stress.
Results
Rigid internal fixation (hollow screws) provided the best initial stability and the least displacement of the bone fragments. A key finding was that under the most severe static loading condition (dorsiflexion with maximum Achilles tendon force), the maximum fragment displacement for all K-wire configurations (≤0.103 mm) was below both the clinically reported acceptable threshold (≤0.5 mm) and the safe healing range (<1 mm), indicating sufficient initial healing stability. Furthermore, K-wires generated significantly lower stress on the bone than the plate, while cannulated screw fixation carried the lowest risk of implant failure. Based on extended observations from clinical literature, K-wire fixation offers potential advantages including a minimally invasive approach, flexible handling, low implant burden, and the possibility of outpatient removal to avoid secondary surgery.
Conclusion
Although rigid implants are biomechanically superior, K-wire fixation provides clinically acceptable initial stability and, combined with its minimally invasive characteristics, represents an attractive alternative. The choice of fixation method requires a comprehensive consideration of individual patient factors (such as bone quality and functional demands) and the overall treatment strategy.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, The Third Affiliated Hospital of Anhui Medical University (The First People's Hospital of Hefei), Anhui Medical University, Hefei, Anhui, China.
Zitieren
APA
Zhou, Z., Liu, M., Kong, L., & Ning, R. (2026). Biomechanical comparison of minimally invasive fixation for sanders II calcaneal fractures: a multi-position finite element study from rigid internal fixation to elastic kirschner wire configuration. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.1857728
Vancouver
Zhou Z, Liu M, Kong L, Ning R. Biomechanical comparison of minimally invasive fixation for sanders II calcaneal fractures: a multi-position finite element study from rigid internal fixation to elastic kirschner wire configuration. Frontiers in Bioengineering and Biotechnology. 2026;14. doi:10.3389/fbioe.2026.1857728
BibTeX
@article{Zhou2026,
author = {Zhou, Zulong and Liu, Mingxiang and Kong, Lingchao and Ning, Rende},
title = {Biomechanical comparison of minimally invasive fixation for sanders II calcaneal fractures: a multi-position finite element study from rigid internal fixation to elastic kirschner wire configuration},
journal = {Frontiers in Bioengineering and Biotechnology},