EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Finite element analysis of impacted canine disimpaction: effects of anchorage systems and T-loop gable bend angles

Xingyu Li, Xibei Li, Shaoyang Yu, Yingyue Zhang, Wenke Yang, Jun Guo, Xueyao Jiang, Xiao Yan, Qiang Zhang, Xiao Yuan

Frontiers in Bioengineering and Biotechnology · 05.06.2026 · 14

DOI: 10.3389/fbioe.2026.1850735 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 05.06.2026. Verfasst von Xingyu Li und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, The Affiliated Hospital of Qingdao University, Qingdao, China. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

To compare the effects of micro-implant (MI) and transpalatal arch (TPA) combined with T-loops of varying gable bend angles on the distalization of mesially impacted canines.

Methods

A finite element model of a mesially impacted left maxillary canine was developed using patient CBCT data. Separate models combining MI or TPA with T-loops featuring α-end angulations of 0°, 15°, and 30° were created. A 1 N retraction force was applied, and canine displacement, stress distribution, and rotation were analyzed.

Results

Increasing the α-end angulation from 0° to 30° changed canine movement from uncontrolled tipping (crown distal/root mesial) to controlled translation (concurrent crown–root distal displacement). The 30°angulation achieved the best root control, minimizing crown–root displacement differences along the X-axis. Among the tested conditions, the 30° angulation showed the most favorable root control pattern in this analysis. Greater angulation also produced lingual root torque and intrusion, maintaining root position within the alveolar bone. Both anchorage systems enabled distalization; however, the TPA group showed slightly greater canine displacement with minor mesial movement and extrusion of anchorage teeth.

Conclusion

Increasing the T-loop α-end angulation converts uncontrolled tipping to controlled translation by synchronizing crown and root displacement. Angulations of 15°–30°are recommended for optimal root control. While MI offers greater anchorage stability, TPA remains a practical noninvasive alternative despite some anchorage loss.

Schlagwörter

Stichwörter der Autor:innen

T-loopcanine impactionfinite element analysismini-implantorthodontictranspalatal arch

Autor:innen und Institutionen

  • Department of Orthodontics, The Affiliated Hospital of Qingdao University, Qingdao, China.
  • School of Stomatology, Qingdao University, Qingdao, China.

Zitieren

APA

Li, X., Li, X., Yu, S., Zhang, Y., Yang, W., Guo, J., Jiang, X., Yan, X., Zhang, Q., & Yuan, X. (2026). Finite element analysis of impacted canine disimpaction: effects of anchorage systems and T-loop gable bend angles. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.1850735

Vancouver

Li X, Li X, Yu S, Zhang Y, Yang W, Guo J, et al. Finite element analysis of impacted canine disimpaction: effects of anchorage systems and T-loop gable bend angles. Frontiers in Bioengineering and Biotechnology. 2026;14. doi:10.3389/fbioe.2026.1850735

BibTeX
@article{Li2026,
  author = {Li, Xingyu and Li, Xibei and Yu, Shaoyang and Zhang, Yingyue and Yang, Wenke and Guo, Jun and Jiang, Xueyao and Yan, Xiao and Zhang, Qiang and Yuan, Xiao},
  title = {Finite element analysis of impacted canine disimpaction: effects of anchorage systems and T-loop gable bend angles},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2026},
  volume = {14},
  doi = {10.3389/fbioe.2026.1850735}
}