Ex vivo localization of wireless implantable microdevice using high-resolution 3D imaging techniques
Frontiers in Bioengineering and Biotechnology · 02.06.2026 · 14
DOI: 10.3389/fbioe.2026.1830115 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 02.06.2026. Verfasst von Teresa Giannattasio und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedicine and Prevention, Tor Vergata University, Rome, Italy. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: HORIZON EUROPE European Innovation Council.
Abstract (Originalsprache)
The CROSSBRAIN EU project aims to address the heterogeneous nature of brain pathologies by developing wireless implantable microbots (µBots, planned dimensions 100 × 100 × 100 μm 3 ) for highly localized neuromodulation. These devices are designed to precisely modulate brain activity with minimal invasiveness, enabling targeted resolution of specific spatiotemporal events, capabilities not currently achieved by existing neuromodulation technologies. A crucial step involves visualizing and ensuring the optimal placement of the µBots in the brain tissue, to study their functionality after implantation. In this preliminary ex vivo study, we used non-functional µBot silicon (Si) dummies matching the lateral dimensions of the intended µBots, with reduced thickness (100 × 100 × 50 μm 3 ) to simplify fabrication and handling. Due to the intrinsic MRI incompatibility of the µBot platform, encompassing both the dummies used in this study and the future functional devices under development, and the limitations of standard histological approaches in reliably identifying and preserving the implant site during processing, we developed an integrated imaging workflow combining 2D and 3D techniques. While standard histological methods and tissue clearing presented substantial limitations in preserving the position of the dummies within the brain tissue, combining histological techniques with 3D X-ray tomography provided a robust strategy. In particular, synchrotron radiation-based X-ray Phase Contrast Tomography (XPCT), with its intrinsic high contrast and resolution, enabled detailed visualization of dummies within the surrounding vascular and cellular architecture. In contrast, conventional micro-Computed Tomography (micro-CT), although more widely accessible, enabled non-destructive guidance for targeted sectioning. Importantly, and in line with the scope of a Brief Research Report, this study presents a preliminary but technically robust investigation conducted within the CROSSBRAIN project, aimed at identifying and establishing an optimized imaging strategy for the visualization of implanted µBots in brain tissue. This methodological framework is intended as an initial step toward future in vivo studies, in which the validated imaging pipeline will be applied to track both dummy and functional devices and to enable subsequent evaluation of foreign body response under physiologically relevant conditions. This ex vivo workflow therefore provides the essential technical foundation for such future investigations and supports the clear positioning of this work as a feasibility and optimization study. This approach could be particularly valuable for new generations of implantable technologies incompatible with MRI and could support future development of personalized neuromodulation therapies by enabling precise device localization and structural tissue assessment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedicine and Prevention, Tor Vergata University, Rome, Italy.
- Institute of Nanotechnology, CNR, Rome, Italy.
- NeuroImmagini Lab, Santa Lucia Foundation, Rome, Italy.
- Department of Engineering and Architecture, University of Trieste, Trieste, Italy.
- Division of Trieste, Istituto Nazionale di Fisica Nucleare (INFN), Trieste, Italy.
- Department of Physics, University of Trieste, Trieste, Italy.
Förderung
- HORIZON EUROPE European Innovation Council
Zitieren
APA
Giannattasio, T., Fratini, M., Brun, F., Brombal, L., Montanaro, M., Palumbo, V., Canichella, A., Ribeiro, J. F., Nizami, S. B., Franceschini, F., Micali, M., Guida, E., Dolci, S., Berdondini, L., Scimeca, M., Mauriello, A., Conti, A., & Toschi, N. (2026). Ex vivo localization of wireless implantable microdevice using high-resolution 3D imaging techniques. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.1830115
Vancouver
Giannattasio T, Fratini M, Brun F, Brombal L, Montanaro M, Palumbo V, et al. Ex vivo localization of wireless implantable microdevice using high-resolution 3D imaging techniques. Frontiers in Bioengineering and Biotechnology. 2026;14. doi:10.3389/fbioe.2026.1830115
BibTeX
@article{Giannattasio2026,
author = {Giannattasio, Teresa and Fratini, Michela and Brun, Francesco and Brombal, Luca and Montanaro, Manuela and Palumbo, Valeria and Canichella, Antonio and Ribeiro, João F and Nizami, Syed Bilal and Franceschini, Flavia and Micali, Marco and Guida, Eugenia and Dolci, Susanna and Berdondini, Luca and Scimeca, Manuel and Mauriello, Alessandro and Conti, Allegra and Toschi, Nicola},
title = {Ex vivo localization of wireless implantable microdevice using high-resolution 3D imaging techniques},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2026},
volume = {14},
doi = {10.3389/fbioe.2026.1830115}
}
EUVIMED