EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Identification of key upper-limb muscles during a standardized reach-to-grasp task toward simplified clinical protocols

Carmen Cabezaolias, Sergio Garcia, Cristina Sanchez, Rodrigo Rodriguez, Rafael Raya, Eloy Urendes

Frontiers in Bioengineering and Biotechnology · 10.04.2026 · 14

DOI: 10.3389/fbioe.2026.1786006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 10.04.2026. Verfasst von Carmen Cabezaolias und 5 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Tecnologías de la Información, Escuela Politécnica Superior, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe,…. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Variability in task execution, target properties, and recording procedures has limited the development of standardized upper-limb surface electromyography (sEMG) reference patterns. Establishing reproducible muscle activation profiles is essential for advancing sEMG-based assessment and motor control applications.

Methods

This study investigated the reproducibility of muscle activation during a highly standardized reach-to-grasp task performed under controlled setup conditions in twenty-seven healthy adults. Participants performed repeated executions of the task under controlled conditions. sEMG signals were processed using time-normalized activation envelopes and cross-correlation analyses allowing for small temporal shifts. Both intra-subject and inter-subject reproducibility were quantified, and a descriptive composite reproducibility measure, combining these two descriptors, was used to summarize overall activation stability.

Results

High reproducibility was observed within subjects, with correlation values ranging from 0.75 to 0.89, and across subjects, with correlations between 0.80 and 0.83. The composite reproducibility analysis highlighted the anterior deltoid, trapezius, lateral deltoid, and biceps brachii as the most reliable contributors to a reproducible activation pattern observed during the reach-to-grasp task.

Discussion

These findings indicate that a reduced subset of muscles can reliably represent the reach-to-grasp movement, supporting the design of simplified electrode configurations that minimize redundancy while preserving essential neuromuscular information. Overall, this work provides a methodological step toward the development of standardized upper-limb activation reference profiles and contributes to the development of efficient sEMG-based assessment, monitoring, and motor control strategies.

Schlagwörter

Stichwörter der Autor:innen

motor controlreach-to-graspreproducibilitysurface electromyographyupper limb

Autor:innen und Institutionen

  • Departamento de Tecnologías de la Información, Escuela Politécnica Superior, Universidad San Pablo-CEU, CEU Universities, Urbanización Montepríncipe, Boadilla del Monte, Spain.

Zitieren

APA

Cabezaolias, C., Garcia, S., Sanchez, C., Rodriguez, R., Raya, R., & Urendes, E. (2026). Identification of key upper-limb muscles during a standardized reach-to-grasp task toward simplified clinical protocols. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.1786006

Vancouver

Cabezaolias C, Garcia S, Sanchez C, Rodriguez R, Raya R, Urendes E. Identification of key upper-limb muscles during a standardized reach-to-grasp task toward simplified clinical protocols. Frontiers in Bioengineering and Biotechnology. 2026;14. doi:10.3389/fbioe.2026.1786006

BibTeX
@article{Cabezaolias2026,
  author = {Cabezaolias, Carmen and Garcia, Sergio and Sanchez, Cristina and Rodriguez, Rodrigo and Raya, Rafael and Urendes, Eloy},
  title = {Identification of key upper-limb muscles during a standardized reach-to-grasp task toward simplified clinical protocols},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2026},
  volume = {14},
  doi = {10.3389/fbioe.2026.1786006}
}
Kostenlos starten →